Essick Air 696 400 Manual De Cuidado Y Uso página 3

Ocultar thumbs Ver también para 696 400:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ASSEMBLY
UNPACKING AND SETTING UP THE UNIT
1.
Remove the two inserts from the top of the humidifier.
2.
Lift off the water bottle covers. Remove the water bottles, lift off the chassis/power pack and
then remove the humidifier cabinet from the carton.
3.
Remove the evaporative wick and all of the remaining packaging materials from the cabinet.
Check to see that you have all of the following items removed from the boxes, accessory kit,
and cabinet before discarding the packaging:
♦ Filler Hose
♦ Caster kit
♦ Bacterial treatment sample
♦ Two Water Bottles
CASTERS
4.
Turn the emptied cabinet upside down. Insert each caster stem into a caster hole on each
corner of the humidifier bottom. The casters should fit snugly and be inserted until the stem
shoulder reaches the cabinet surface.
5.
Turn the cabinet right side up.
EVAPORATIVE WICK
6.
Insert the 1041 wick into the unit. The wick has a mounting
rib on the top edge which hooks over a rib at the inside back
of the cabinet. This allows the wick to hang in the water
channel (see cutaway illustration for details). Hang wick into
cabinet as shown.
OPTIONAL AIR CLEANING FILTER
(included on 427 and 697 models; sold separately on 696)
7.
If available, install the 1051 AirCare® filter at the back of the
unit. The filter has tangs that engage into four keyhole slots
that mount the AirCare® filter onto the outside of the back of the cabinet.
FILLING INFORMATION
8.
Your humidifier is equipped with two water bottles. On the 696 and 697 models each bottle
holds 2.6 gallons. The 427 model bottles hold 2.75 gallons each.
9.
A fill hose that fits most faucets is provided with your humidifier. Fill the bottles with cool, fresh
(preferably unsoftened) water. If you only have softened water available in your home, you
can use it, but mineral buildup will occur more quickly.
NOTE: For optimum running time, fill each water bottle, tighten the cap, and place inside unit. Do
not fill the reservoir bucket, as overfilling will result in water damage. Use only the bottles provided.
One bottle will drain until the reservoir is filled. Remove the partially emptied bottle and refill it.
Place back in humidifier cabinet.
CAUTION: When filling, be careful not to pressurize the bottle by overfilling it. Bottle damage can
result from this, and will not drain properly.
NOTE: On initial fill up, it will take approximately 20 minutes for the reservoir to fill because the dry
wick has to absorb water. Subsequent fillings will take approximately 12 minutes, since the wick is
already saturated.
10. After the filling process is complete, insert the water bottles into the humidifier, placing them
with the valve cap end down, so that the groove in the water bottle faces the inside.
11. After filling, replace the water bottle cover and place the chassis/power pack unit into the
cabinet, so it fits without tipping or rocking.
♦ Evaporative Wick
♦ Two end covers
♦ Optional Air Care ® filter (included on 697 and
427 models; sold separately on 696 model
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

697 500427 300

Tabla de contenido