Then, you press the "SET" button shortly,
arrow keys. By briefly pressing the "SET" button, there will be access to adjust the temperature
difference between the setpoint and emergency shutdown of the heating cable at an excessively high
water temperature. If the setpoint plus this set value is reached, the heating cable is switched off
until the temperature in the aquarium has dropped again below the setpoint.
By pressing the "SET" button again, you can set the alarm. When reaching the setpoint plus the
adjusted value, you will hear a beep.
unit activates the power socket No. 1 and switches the consumer (heating) on. The heating cable is
controlled by the timer and power socket No. 2.
If you keep pressing the "SET" button for a quite a while, you will reach the timer menu. Here, you
can set the time also by pressing the "SET" button and the arrow keys. Then, the time how long the
heating cable should be turned on and switched off has to be adjusted. A mode of 15 minutes each
have been proved suitable. Again, the value to be changed is selected and then adjusted using the
arrow keys by pressing the "SET" button.
By pressing the OK button you can leave the setting menu.
The heat controller duo has got a rechargeable battery so the programmed data will not
be lost in case of power failure. After starting the unit up, it takes about 24 hours until the
battery is charged and the data remain stored.
For safety reasons, you should control the nominal values, especially after a power failure.
5. Technical Data
Display:
Measurement range:
Resolution:
Loading capacity of contact:
Air Humidity:
Adjustment range:
Adjustment accuracy:
Power requirements:
Humidity:
6. Warranty
Should any defect in material or workmanship be found within 12 months of the date of purchase AB
Aqua Medic GmbH undertakes to repair or, at our option, replace the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid. The
warranty term is not applicable on the all consumable products.
Proof of Purchase is required by presentation of an original invoice or receipt indicating the dealer's
name, the model number and date of purchase, or a Guarantee Card if appropriate. This warranty
may not apply if any model or production number has been altered, deleted or removed,
unauthorised persons or organisations have executed repairs, modifications or alterations, or damage
is caused by accident, misuse or neglect.
We regret we are unable to accept any liability for any consequential loss.
Please note that the product is not defective under the terms of this warranty where the product, or
any of its component parts, was not originally designed and / or manufactured for the market in
which it is used. If your AB Aqua Medic GmbH product does not appear to be working correctly or
appears to be defective please contact your dealer in the first instance.
Before calling your dealer please ensure you have read and understood the operating instructions. If
you have any questions your dealer cannot answer please contact us.
Our policy is one of continual technical improvement and we reserve the right to modify and adjust
the specification of our products without prior notification.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
6
the
setpoint appears flashing and can be changed with the
As soon as the temperature falls below the adjusted value, the
0.1°C
0.0 up to +50.0°C
0.1°C
1,200 Watt at 220 V AC
below 80%
16 – 40°C
+/- 1°C
220 V / 50 Hz
< 85%
- Technical changes reserved – 09/2015