INSTALLATION INSTRUCTIONS

Water Supply
Recommended
Maximum
Hot Water Temperature
65 C° (~150F)
80 C° (~175F)
Working Pressure
3 BAR (~45PSI)
5 BAR (~75PSI)
In case of pressures over 5 BAR (~75 PSI), we
positioning hole with the housing of the fitting
recommend to use a pressure reducer.
screw (4.E), then tighten the latter.
Warning! Do not force the screw (4.E). Excessive
Before proceeding with the assembly, purge the
hot and cold water pipes so as to avoid the
tightening can affect the correct function of the
accumulation of dirt and impurities that could
system or damage it. The thermostatic cartridge
affect the function of the faucet.
is equipped with a safety anti-scalding retainer
set at 100°F (38°C). For higher temperatures
FIG. 01
push the button on the adjustment handle. In
Remove the protection covers (1.A) using a
case of hot or cold water pressure failure, the
screwdriver. Use the plug (1.B) if necessary.
flow will automatically stop. With a screwdriver
loosen the stop cocks (4.F) in anti-clockwise
FIG. 02
direction.
Fit the faucet body (2.A) to the wall with the
two upper outlets pointing towards the flow
FIG. 05
elements. Connect the hot water supply to the
Remove the protection tape of the adhesive
left inlet and the cold water supply to the right
sponge (5.D) and apply it on the back of the
one.
plate (5.C). Fit the sliding flat washers (5.B) and
(5.A) on the plate (5.C) and install it on the
FIG. 03
thermostatic body till it is flush to the wall.
The depth of the wall niche must correspond
FIG. 06
(wall coating included) to the tolerance given
by the MIN/MAX references given on the
Control handles installation.
plastic cover (3.A).
For the upper portion with the cartridge, follow
Once all connections have been carried out,
the instructions given below:
activate the faucet at the working pressure
Fit the insert (6.L) on the bar of the cartridge
(we recommend maintaining the water flow
so as to obtain the correct alignment once the
for a few minutes so as to purge the system
handle (6.F) has been installed and lock using
from any debris and/or dirt inside the piping).
the screw included (6.I). Fit the handle (6.F)
Temporarily remove the protection cover (3.A)
and tighten the grub screw (6.G). Complete by
to check if there are leakages and if the system
positioning the finishing cap (6.H).
works regularly, reinstall the protection cover
For the lower portion with the thermostatic
(3.A) and finish the external wall surface.
cartridge, follow the instructions given below:
fasten the peg (6.E) on the bar of the thermostatic
FIG. 04
cartridge and install the handle (6.A) placing
Remove the protection cover (3.A) as shown
the ring (6.D) in between without moving the
in FIG. 03. With a screwdriver fasten the stop
bar so as to not compromise the cartridge
cocks (4.F) in clockwise direction, loosen the
calibration. Tighten the grub screw (6.B) and
fitting screw (4.E) using the proper wrench
place the finishing cap (6.C).
and pull out the test plug (4.D). Insert the o-ring
(4.C) and the sleeve (4.B) on the thermostatic
body. Use a small quantity of the special grease
included to lightly lubricate the o-rings of the
thermostatic cartridge (4.A). Insert the cartridge
in the faucet housing carefully aligning the
Istruz. art. 7369100.indd 4-6
FIG. 01
Minimum
15 C° (~60F)
0.5 BAR (~7PSI)
FIG. 03
FIG. 05
FIG. 02
FIG. 06
FIG. 04
FIG. 07
FIG. 08
26/04/11 10:08