Munters JAZ 10 D Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
1
Axle
2
Axle bracket
3
Washer
4
Wheel dia. 200
5
Wheel ring
6
Screw M5×16
7
Washer M5
8
Nut M5
9
Plastic cap
10
Handle
12
Screw M5×30
To assemble the heater, proceed as follows (see Fig. 2):
Slide axle (1) through axle brackets (2). Assemble in order:
wheels (4), washers (3), wheel rings (5) on axle ends, by
tapping lightly. Fix the axle assembly to the heater tank using
four screws (6), washers (7) and nuts (8).
Fix plastic caps (9) on handle (10). Connect handle (10) to
heater tank using four screws (12), washers (7) and nuts (8).
JAZ 60 D
Fig. 3
1
Axle assembly
2
Wheel
3
Cap nut
4
Screw M5x16
5
Washer D.5
6
Nut M5
7
End cap
8
Heater support
9
Rear handle
10
Screw M5x30
Before installation and use, assemble the loose parts as follows
(see Fig. 3):
Connect axle assembly (1) to heater tank using four screws
M5x16 (4), washers (5) and nuts (6).
Slide wheels (2) on axle assembly. Lock wheels using cap nuts
(3) and tapping lightly.
Insert end caps (7) on rear handle (9) and support (8). Connect
rear handle (9) and support (8) to heater tank using screws
M5x30 (10), washers (5) and nuts (6) as shown.
4. Installation
Position the heater upright on a flat, level, non-
flammable, solid surface.
Direct-fired heaters are intended for use in outdoor
open areas or in indoor well ventilated premises. For
indoor use, provide permanent ventilation openings of at
least 25 cm²/kW, equally distributed between floor and high
level.
© Munters 2013
Munters reserves the right to make alterations to specifications, quantities, etc. for production or other reasons, subsequent to publication
GB
1
MINIMUM VENTILATION REQUIREMENTS
2
Model
2
10 D
2
20 DH
2
20 DW
4
30 D
8
40 D
8
60 D
2
1
Direct-fired heaters may cause carbon monoxide (CO)
4
poisoning when incorrectly used, e.g indoors without
adequate air circulation, or if not properly working. CO
poisoning may lead to death. Early signs of CO poisoning
are headache, dizziness and/or nausea. If you have these
signs, get fresh air at once, shut off the heater and check
the heater operation and installation. Call technical service
if needed. Some people such as pregnant women, persons
with heart or lung diseases, or under the influence of
alcohol, or at high altitudes are more affected by CO than
others.
Do not place the heater near walls, corners or low
ceilings.
Do not place the heater on moving vehicles or where it
can tip over.
Keep the heater away from flammable, combustible,
explosive or corrosive materials.
Keep the heater away from curtains, tarpaulins,
canvas or similar enclosure materials that could block the
air inlet and outlet and/or cause fires.
NEVER BLOCK OR RESTRICT THE AIR INLET AND
OUTLET FOR ANY REASON.
Keep the power cable away from heat sources, sharp
edges, cutting and moving parts.
Do not expose directly to the weather or to excessive
humidity.
Do not place the heater in the immediate surroundings
of a bath, shower or swimming pool.
Follow general and special fire safety regulations in
force. In doubt, contact the local authorities having
jurisdiction for information. In any case ensure the
following minimum safety clearances from materials or
1
objects in the surroundings of the heater DURING and
2
AFTER operation:
2
4
MINIMUM SAFETY CLEARANCES
8
Sides:
8
Air inlet:
4
Top:
1
Hot air outlet:
1
Floor:
4
Do not attach direct-fired heaters to air ducting.
5. Instructions for Use
MAKE SURE THAT THE AIR INLET AND OUTLET ARE
NOT BLOCKED OR RESTRICTED DURING OPERATION.
DO NOT COVER THE HEATER DURING AND AFTER
OPERATION.
Some parts of the heater (outlet, external surfaces)
become very hot DURING and/or AFTER operation. Do not
touch! Use personal protective equipment (PPE) as
needed.
Children should be supervised to ensure that they do
not play with the appliance.
The appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge.
JAZ
Opening Area
300 cm²
550 cm²
550 cm²
800 cm²
1050 cm²
1600 cm²
0.6 m
1 m
1.5 m
3 m
0 m
6
.