Warning! :
Problems and failures may occur even when the appliance is used properly. Here is a list
of the mist probably situations and controls that the operator should perform to avoid
applying to a service centre unnecessarily.
If the problem is not solved after the necessary controls, turn off the appliance
immediately, unplug it, cut off any supplies and apply to a service centre.
DISPLAY MSG
DEFECT/ANOMALY
THE KEYPAD DOES
NOT START
THE HEATING SYSTEM
DOESN'T WORK
Instructions manual and use
Electric tilting pan CPE25
HOW TO PROCEED IF ...
DESCRIPTION
Vat water level insufficient to allow the heating.
The alarm stops automatically when the water level reach the
lower sensor-probe inside the vessel. If this alarm occurs with
water at the right level:
Apply to a service centre for assistance.
Intervention of the safety thermostat:
Apply to a service centre for assistance.
Overheating in the relay card.
The alarm stops automatically when the electric circuit temperature
return into the values pre-established (< 60° C).
Anomaly in the ventilation system:
Apply to a service centre for assistance.
Damaged temperature probe (message flashing):
Apply to a service centre for assistance.
Error in connection between relay Board and the keyboard tab.
(The possible presence of moisture in the relay Board):
apply to a service centre for technical assistance.
OPERATION
Verify any cut-off on the electric feed (main switch of the
electrical net).
Verify any accidental pressing of the emergency button,
otherwise:
Apply to a service centre for assistance.
Verify that the vat must be in horizontal position. The led of
the key must be swithed off otherwise:
Apply to a service centre for assistance.