An alarm is considered to be any serious incident that may compromise the safety of the
installation or the equipment itself. If this happens, the equipment stops automatically, displaying
an acoustic warning and a message on the screen. User action is required to correct the issue.
Press OK to resume production once the problem has been resolved.
Message
No flow
Open circuit
Short circuit
Temperature
If you are unable to locate the cause of the problem, do not hesitate to consult your technical service.
52
Cause
Filtration pump stopped,
or speed too low
Filter selector valve in wrong
position
Air accumulation in the upper part
The cell electrodes are misplaced
Disconnected or damaged cell
cable
Unsalted pool water
Misplaced cell electrodes
Badly connected cell wires, or wires
that make bad contact
Internal equipment failure
Ambient temperature too high
Corrective Action
Check the correct operation of
the pump. Increase its speed if
necessary
When the chlorinator is running,
the selector valve must be in the
"filtration" position
Let it expel itself. Purge if necessary
Place the electrodes correctly, one
per vessel slot.
Check the cell connections,
especially that the connectors have
good contact
Adding salt to the water
Check that there are no electrodes
touching each other
Check the cable connections
Contact your technical service
Try to install the equipment in a
ventilated place and avoid direct
sunlight