12
5.2 Saving the position
Positions can be saved on buttons 1, 2 or 3.
• Move table to required height.
• Press button "S". "S" symbol starts to flash for 3 seconds on the display.
• Press button on which position should be saved (button 1, 2 or 3). The height
has been saved.
• "S1" (S2, S3) appears in the display for approx. 1 second (see Figure 2 in picture
section).
5.3 Retrieving the saved position
• Press button 1, 2 or 3 and hold it down until the required position is reached.
• The current height appears on the display during movement (see Figure 3 in
picture section).
5.4 Individually adapting the control unit
The control unit is displaying 68 cm as the preset height. Because of different table
top thicknesses, for example, it may be necessary to reset the height.
• Press buttons "S" and " " or "" simultaneously
• Display of current table height.
• Release button (See Figure 4 in picture section).
5.5 Blocking the control unit
The display has a "zero function", i.e. if the control unit is not used for 10 seconds,
it goes into standby mode and is blocked.
• Display blocked: a bar in the middle of the display illuminates (see Figure 6 in
picture section).
5.6 Unblocking the display
• Press button S for five seconds until a number can be seen on the control
element.
• Press button 1, 2 or 3 and hold it down until the required position is reached (see
Figure 7 in picture section).
5.7 Changing unit of measurement from "cm"--> "inches"
• Press button "S" for approx. 4 seconds.
• The unit of measurement on the display changes (see Figure 5 in picture
section).
Lifting device will not
move
"E-01" displayed
If "-" cannot be seen: check all plug-in connections
with the mains plug disconnected /
wait for 10 minutes / plug in the mains plug /
"-" illuminates again / press button S for five seconds
until a number can be seen on the control element
If "-" can be seen: check whether movement is being
blocked by an object
Loss of position, move lifting device down and
perform a reset