Important; Set Up Instructions - Westinghouse ST Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
15ft
1
2
Operating
Tripped
3
4
R U N
P
S T O
5
E R Y
B A T T
A T O R
I N D I C
6
SET UP
1.
Operating
Tripped
2.
3.
4.
5.
6.
7.
8.
9.
7
8
READ ALL SAFETY INFO IN THIS ST SWITCH MANUAL
AND GENERATOR MANUAL. GENERATOR MUST BE OFF
WHILE SETTING UP ST SWITCH
Place compatible generator outside in well vented area
at least 15ft away from any doors or windows. NOTE:
Confirm generator works properly, battery is connected,
and oil and fuel levels are correct. Make sure generator
is off before connecting ST Switch.
IMPORTANT: Confirm breakers on generator and ST
Switch are in operating position.
Attach one end of the generator control cable to the Smart
Switch Ready outlet on the generator.
Plug in the L14-30 plug on the generator power input cord
to the L14-30R outlet on the generator.
Switch the generator engine control switch to RUN and
confirm the battery indicator light illuminates on the
generators control panel.
Place the ST Switch inside away from damp areas. Do not
leave outside.
Plug grounded extension cord (not provided) into
household 120V outlet and plug in other end into the utility
power input on the ST Switch box. The green utility power
indicator will light up.
Attach the other end of the generator control cable to the
control cable outlet on the ST Switch.
Connect the appliances you want to run to the 5-20R
120V 20A outlet on the ST Switch.
9
11

Publicidad

Tabla de contenido
loading

Tabla de contenido