3B SCIENTIFIC PHYSICS 1000618 Instrucciones De Manejo página 6

Triodo de gas
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
3. Technical data
Gas filling:
Filament voltage:
Anode voltage:
Anode current:
Grid voltage:
Glass bulb:
Length of tube:
4. Operation
To perform experiments using the gas triode the
following equipment is also required:
1 Tube holder S
1 DC Power supply 500 V (@115 V)
or
1 DC Power supply 500 V (@230 V)
2 Analogue multimeter AM50
4.1 Setting up the tube in the tube holder
The tube should not be mounted or removed
unless all power supplies are disconnected.
Press tube gently into the stock of the holder
and push until the pins are fully inserted.
Take note of the unique position of the guide
pin.
4.2 Removing the tube from the tube holder
To remove the tube, apply pressure with the
middle finger on the guide pin and the thumb
on the tail-stock until the pins loosen, then
pull out the tube.
5. Example experiments
5.1 Discharge, evidence of positive charge
carriers
Set up the circuit as in fig. 1.
To demonstrate the existence of positive
charge carriers (He
at a maximum heater filament voltage U
measure the current I
sign.
5.2 Non-self-sustaining discharge
Set up the circuit as in fig. 2.
Record a characteristic curve of I
(= U
) for various filament voltages U
U
A
G
V ...7.5 V).
At about 25 V the anode current I
considerably in the gas triode. This increase is
Helium
≤ 7.5 V AC/DC
max. 400 V DC max.
10 mA typ. at U
= 300 V
a
max. 30 V
130 mm diam. approx
260 mm approx.
1014525
1003307
1003308
1003073
+
ions) for gas discharge
taking note of the
G
against
A
increases
A
accompanied by the appearance of a blue lumi-
nescence. It is apparent that there are many
more charge carriers transporting charge than in
the vacuum triode (since there are He
well as thermal electrons).
5.3 Self-sustaining discharge
Set up the circuit as in fig. 3.
Gradually increase the anode voltage U
and determine the striking voltage U
gas discharge.
Reduce the anode voltage U
self-sustaining discharge ceases. Record
this extinguishing voltage U
5.4 Simplified Franck-Hertz-set-up
Experiment for demonstrating discontinuous
energy emission resulting from inelastic colli-
sions between between electrons and helium
atoms. The electrons have to travel through a
decelerating reverse-potential field between the
grid and anode, so that they only arrive at the
anode if they possess sufficient kinetic energy.
Only then do they contribute to the current I
between anode and ground.
Set up the circuit as in fig. 4.
For a reverse polarity U
raise the accelerating potential U
to 70 V and measure the anode current I
Plot a graph of the anode current as a func-
tion of the accelerating voltage.
Up to an accelerating potential of about 24 V,
the anode current increases but then it drops
suddenly. As the accelerating potential is further
increased the current increases once again but
after another 20 V or so it drops again.
A plot of the anode current should exhibit two
clear maxima. If this is not perceptible, the fila-
ment voltage should be lowered somewhat.
,
F
(5
F
2
+
ions as
A
for the
S
again until the
A
.
E
A
of 6 V, gradually
R
from 0 V
A
.
A