Parameter
Menu level
Pr01
M – 9 – 6 – 01
Pr02
M – 9 – 6 – 02
Pr03
M – 9 – 6 – 03
Pr04
M – 9 – 6 – 04
Pr05
M – 9 – 6 – 05
Pr06
M – 9 – 6 – 06
Pr07
M – 9 – 6 – 07
Pr08
M – 9 – 6 – 08
Pr09
M – 9 – 6 – 09
Pr10
M – 9 – 6 – 10
Pr11
M – 9 – 6 – 11
Pr12
M – 9 – 6 – 12
Pr13
M – 9 – 6 – 13
Pr14
M – 9 – 6 – 14
Pr15
M – 9 – 6 – 15
Pr16
M – 9 – 6 – 16
Pr17
M – 9 – 6 – 17
Pr18
M – 9 – 6 – 18
Pr19
M – 9 – 6 – 19
Pr20
M – 9 – 6 – 20
Pr21
M – 9 – 6 – 21
Pr22
M – 9 – 6 – 22
Pr23
M – 9 – 6 – 23
Pr24
M – 9 – 6 – 24
Pr25
M – 9 – 6 – 25
Pr26
M – 9 – 6 – 26
Pr27
M – 9 – 6 – 27
Pr28
M – 9 – 6 – 28
Pr29
M – 9 – 6 – 29
Pr30
M – 9 – 6 – 30
Pr31
M – 9 – 6 – 31
Pr32
M – 9 – 6 – 32
Pr33
M – 9 – 6 – 33
Pr34
M – 9 – 6 – 34
Pr35
M – 9 – 6 – 35
Pr36
M – 9 – 6 – 36
Pr37
M – 9 – 6 – 37
"Default settings" (Menu M – 9 – 6)
Description
Ignition cycle maximum time
Start time
Time interval between the two brazier cleaning
operations
Screw feed motor reducer ON time in ignition
phase
Screw feed motor reducer ON time in start phase
Screw feed motor reducer ON time in power 1
work phase
Screw feed motor reducer ON time in power 2
work phase
Screw feed motor reducer ON time in power 3
work phase
Screw feed motor reducer ON time in power 4
work phase
Screw feed motor reducer ON time in power 5
work phase
Alarm delay
Brazier cleaning duration
Flue gas minimum temperature to consider the
boiler on
Flue gas maximum temperature
Flue gas temperature threshold for igniting the
exchangers (UNUSED)
Flue gas intake device speed in ignition phase
Flue gas intake device speed in start phase
Flue gas intake speed in power 1 work phase
Flue gas intake speed in power 2 work phase
Flue gas intake speed in power 3 work phase
Flue gas intake speed in power 4 work phase
Flue gas intake speed in power 5 work phase
Exchanger 1 motor speed in power 1 work phase
(UNUSED)
Exchanger 1 motor speed in power 2 work phase
(UNUSED)
Exchanger 1 motor speed in power 3 work phase
(UNUSED)
Exchanger 1 motor speed in power 4 work phase
(UNUSED)
Exchanger 1 motor speed in power 5 work phase
(UNUSED)
Flue gas intake device switch-off threshold (in
switch-off phase)
Flue gas intake device speed in brazier cleaning
phase
Screw feed motor reducer ON time in cleaning
phase
Flue gas intake device encoder enabling
(UNUSED)
Screw feed brake time
Pump activation threshold
Water pressure switch enabling (UNUSED)
Water pressure threshold (UNUSED)
Screw feed motor reducer ON time in DHW
power work phase
Flue gas intake speed in DHW power work
phase
Display writing
Measurement
IGNIT- MINUTES
START MINUTES
BRAZIER CLEANING
IGNIT- SCREW FEED
START SCREW FEED
POWER 1 SCREW FEED
POWER 2 SCREW FEED
POWER 3 SCREW FEED
POWER 4 SCREW FEED
POWER 5 SCREW FEED
ALARMS DELAY
BRAZIER CLEANING
MINIMUM THRESHOLD
MAXIMUM THRESHOLD
FAN THRESHOLD
IGNIT FLUE GAS SPEED
START FLUE GAS
SPEED
P 1 FLUE GAS SPEED
P 2 FLUE GAS SPEED
P 3 FLUE GAS SPEED
P 4 FLUE GAS SPEED
P 5 FLUE GAS SPEED
AIR 1 SPEED
AIR 2 SPEED
AIR 3 SPEED
AIR 4 SPEED
AIR 5 SPEED
THRESHOLD OFF
FLUE GAS-INTAKE
DEVICE CLEANING
CLEANING SCREW
FEED
ENCODER
BRAKE TIME
PUMP THRESHOLD
WATER PRESSURE SW.
PRESSURE
THRESHOLD
DHW SCREW FEED
DHW FLUE GAS-INTAKE
DEVICE
22
Value field
Minutes
5 – 25
Minutes
2 – 12
Minutes
3 – 240
Seconds
0.1 – 8.0
Seconds
0.1 – 8.0
Seconds
0.1 – 8.0
Seconds
0.1 – 8.0
Seconds
0.1 – 8.0
Seconds
0.1 – 8.0
Seconds
0.1 – 8.0
Seconds
20 – 90
Seconds
0 – 120
°C
40 – 180
°C
110 – 250
°C
50 – 210
Revs/min
500 – 2800
Revs/min
500 – 2800
Revs/min
500 – 2800
Revs/min
500 – 2800
Revs/min
500 – 2800
Revs/min
500 – 2800
Revs/min
500 – 2800
Volt
65 – 225
Volt
65 – 225
Volt
65 – 225
Volt
65 – 225
Volt
65 – 225
°C
50 – 180
Revs/min
500 – 2800
Seconds
0.1 – 8.0
On – off
On – off
Seconds
0 – 0.5
°C
20 – 70
On – off
On – off
Bar
1.5 – 3.0
Seconds
0.1 – 8.0
Revs/min
500 – 2800
Database
25
2
70
2,0
1,8
2,2
3,2
4,2
5,7
7,0
30
40
50
250
60
2100
2200
1700
1800
1900
2000
2150
65
65
65
65
65
70
2400
2,2
On
0,2
55
Off
2,5
7,0
2150