Secondary Pump Configuration (optional)
The Secondary Pump Kit (sold separately) allows you to finely adjust the amount of water you
want to treat. The Pump (G) recirculates water and air on itself, reducing consumption because it
does not have to fulfill the task of loading the water, but is optimized completely for skimming.
The Secondary Pump Configuration (Recirculating) allows the adjustment of three parameters
independently:
1.
Water flow rate to the skimmer is controlled by the Secondary Pump (O)
2.
Foam level is controlled by the threaded rod on the Drain Tube (E)
3.
Air flow to the skimmer is controlled by the air intake screw of the Air Silencer (F)
The Secondary Pump Kit consists of:
O.
Secondary Pump
P.
Venturi Extension
Q.
O-ring
R.
Connecting Hose
S.
Venturi O-ring x 2
T.
Hose Clip x 2
Secondary Pump Assembly
1.
Remove the Pump (G).
2.
Remove the Water Control Screw (K) from the Venturi Injector (L).
3.
Slide the two O-rings (S) on Venturi Injector (L) cavities.
4.
Slide the Venturi Extension (P) onto the Venturi Injector (L)
5.
Remove the cap from the Support Base (A) just under the Pump (G) by unscrewing the
compression ring (A.1).
6.
Insert O-ring (Q) into Compression Ring (A.1)
7.
Re-attach Pump (G) by inserting the Venturi Extension (P) into the Base (A) ensuring
contact with O-ring (Q) and secure tightly with the Compression Ring (A.1).
8.
Tighten the compression ring linking the Pump (G) back onto the Reaction Column (C).
9.
Connect the Secondary Pump (O) with the Connecting Hose (R) to the inlet connector (C.1)
and secure the Hose with Clips (T) as shown in Figure 5.
Figure 4
15