Technical Data; Key To Symbols - Urmet 1083/24 Manual De Instalación

Ocultar thumbs Ver también para 1083/24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
ENGLISH
Power supply in CAT II 2500 V. Once installed, the power supply is subject to transient voltages higher than
those of the overvoltage category for which is was designed. For this reason, an additional transient voltage
protection is required outside the device.
INSTALLATION
The device must be installed inside an electric panel or cabinet.
CONNECTION OF THE POWER SUPPLY UNIT
DESCRIPTION OF THE TERMINALS
N, L
Input voltage 110/230 V~
}
V-
Call-Forwarding interface power voltage output
V+

TECHNICAL DATA

Power supply: .................................................................................................................100-240 V~ 50/60 Hz
Power: ............................................................................................................................................max. 12 W
Secondary output: ................................................................................................................. 24 V
Power dissipated after after 1 hour of functioning: ........................................................Max 11 Wh (~40 KJ)
Dimensions (WxDxH): ................................................................................36 (2 DIN modules) x 98 x 60 mm

KEY TO SYMBOLS

Symbol
Direct input voltage
~
Alternating input voltage
See the installation manual of the device
DS1083-079C
Installation on DIN bar (2 x 18 mm modules)
V- V- V+ V+
NC NC N L
Power supply
110/230 V~
Description
1
2
To Call-Forwarding interface
Wires with cross-section area of 0.5 mm
larger must comply with IEC 60332-1-2; wires
with cross section area smaller than 0.5 mm
must comply with IEC 60332-2-2.
or
2
2
0,42 A
3

Publicidad

Tabla de contenido
loading