6. Shipping, Handling and Storage

For the shipping and handling of the packages:
PICTURE 08
LAR-15LMB-HD
Orientation:
- Keep it in a dry and
ventilated location;
-Storage temperature: 20°
Celsius;
-Maximum
pilling:
boxes;
- Storage Humidity: 50%
For the shipping and handling without package:
- Shipping and/or handling as displayed below:
Handling /
Shipping
16
PICTURE 09
LAR-25LMB-HD
*Dimensions in millimeters.
4
FIGURA 10

7. Observed Standards

Guidelines CE 2006/42/EC

8. Maintenance

The maintenance must be a group of procedures that have
the objective of keeping the appliance in its best condition
of operation and increasing its life expectancy and safety.
* Cleaning – Check the item 3.4 Cleaning of this Manual.
* Electrical wiring – Check all the cables to avoid deterio-
ration and all the electrical contacts about their tightening
and corrosion
* Contacts – ON and OFF Switch, emergency switch, reset
button, eletric circuits,etc. Check the appliance so that all
the components are working correctly and that the opera-
tion is working normally
* Installation – Check the installation of your appliance ac-
cording to the item 2.1 Installation of this manual.
1 – Items to be verified and implemented monthly:
- Check the electrical installation;
- Check the outlet tension;
- Measure the operating current and compare it to the no-
minal one;
- Check all the eletrical terminal tightening of the appliance,
to avoid bad contact;
- Check the possible clearance of the shift of the electric
motor;
- Check the wiring and the electric cable to avoid its overhea-
ting, deficient isolation and mechanical breakdown.
2 - Items to be verified and implemented every 3 months:
- Check the electric components as ON/OFF switch, emer-
gency button, reset button, and eletric circuit related to
overheating, deficient isolation and mechanical breakdown.
- Check possible loosens in the bearings
- Check retainers, o´rings, v´rings and other sealing systems.