King gates Star Open Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

QUICK GUIDE:
CAUTION! - Do not install the boom gate without ha-
ving read all the instructions!
Install the boom gate, the control (key selector switch or push but-
ton panel) and safety devices (emergency stop, photoelectric cells,
sensitive edges and flashing lights) after which do the wiring fol-
lowing the diagram fig. 1.
01. Prior to turning power on check that the bar is well balanced,
adjusting the balancing spring if necessary.
02. Release the boom gate using the special spanner and check that
the bar can move without any effort for the whole length of travel.
03. Power the unit and check that on terminals 1-2 voltage is 230
V AC and on terminals 5-6 it is 24 V d.c.; the LEDs on the active
inputs must turn on and the OK LED must flash at a frequency of
1 flash/second.
04. Check correspondence of the two FCA and FCC LEDs: when
the bar is closed only the FCC LED should turn off and when it is
open only the FCA should turn off.
05. To exploit the slowing down function it is necessary that the
limit switch triggers about 20° before the actual stopping point is
reached; if necessary adjust the two cams until the limit switch
triggers at the point required.
06. Check that all the function switches are in the "OFF" position.
This means it is in the manual functioning mode, that is, with the
button pressed. Lock the boom gate with the bar at a 45° angle
so it can move freely in both directions. Now give a brief command
pulse on the OPEN input and if the bar does not move in the ope-
ning direction proceed as follows:
a) Turn the electricity off to the boom gate
b) Unplug the "MOTOR" connector and replug it after it has
been turned 180°
c) Unplug the "LIMIT SWITCH" connector and replug it after it
has been turned 180°
1
FUNCTIONS
FCA
FCC
PAUSE
STOP
WORKING
AMPERE
TIME
OK
07. See if rotation direction is right, repeating the procedure de-
scribed above.
08. Temporarily adjust the STOP_AMPERE and WORKING
FORCE trimmer to the maximum of the travel, PAUSE TIME to
minimum and SLOWING DOWN FORCE to halfway travel. Now
try and carry out a complete manoeuvre until the limit switch is
reached and the subsequent stopping point and then try the ma-
noeuvre in the opposite order.
09. Set the FUNCTIONS dip-switches as required:
Switches 1-2:
Off Off
On Off
Off On
On On
Switches 3:
On
Switches 4:
On
Switches 5:
On
Switches 6:
On
Switches 7:
On
Switches 8:
On
Switches 9:
On
Switches 10:
On
10. Adjust the two trimmers WORKING FORCE and SLOWING
DOWN FORCE until obtaining the force and speed required du-
ring, respectively, the travelling and slowing down phases; only now
adjust the STOP_AMPERE trimmer until the triggering threshold
required is obtained.
If in the automatic functioning mode, adjust the PAUSE TIME
trimmer as wanted.
44
SLOWING
FORCE
DOWN
43
FORCE
42
41
15
CLOSE
14
OPEN
13
STEP BY STEP
12
PHOTO2
11
PHOTO
10
STOP
9
8
7
+ (24v)
6
- (0 v)
5
4
+
-
3
2
1
=
"Manual" movement (Man Present)
=
"Semiautomatic" movement
=
"Automatic" movement (Automatic Closing)
=
"Automatic + Always Closes" movement
=
Condominium function
=
Cancels STOP in the Step-by-Step cycle
=
Pre-flashing
=
Flashing also in Pause
=
Recloses straight after Photocell
(only if on Automatic)
=
Safety (Photocell) also in opening
=
Bar open indicator becomes traffic light in
the "one-way" mode
=
Functioning in the "Traffic light in both di-
rections" mode
AERIAL
2¯ Ch
RADIO
CLOSE
OPEN (TIMER)
STEP BY STEP
PHOTO2
PHOTO
STOP
BAR OPEN INDICATOR
COURTESY LIGHT
COMMON
24 VDC
max 200 mA
LUCY 24 VDC
max 25 W
230 VAC
50-60 Hz
1