Please read all instructions before installing
PIR Application-Specifi c
SPECIFICATIONS
Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent .................................................. 25-500 Watts
Time Delay ................................................................ 5 minutes
Environment ..................................Residential Indoor use only
Operating Temperature ............... 32° to 131°F (0° to 55°C)
Humidity ...................................... 95% RH, non-condensing
Electrical Supply Wire ..... minimum temp rating 167° F (75°C)
Tools Needed
Insulated Screwdriver
Wire Strippers
DESCRIPTION AND OPERATION
The RS-100U Application-Specifi c Wall Switch Occupancy Sensor is designed
to replace a residential light switch. It is ideal for laundry rooms, utility rooms,
storage areas, closets and any other indoor area in a residential building where
occupancy sensor-based automatic ON/OFF controls are desirable. The sensor
requires no adjustments to operate successfully in those particular applications
for which it was designed.
Lighted Switch
To help you locate the RS-100U in a dark room, an amber LED illuminates the
ON/OFF button while the controlled light (load) is OFF. When the load is ON, the
LED is OFF.
Push Button
The push button can be used to manually turn ON and OFF the load. To turn the
load OFF, tap fi rmly on the push button once. The lighted switch will turn ON
and the load will turn OFF. If the load is turned OFF manually, Automatic-ON is
reenabled when no motion is detected for 5 minutes.
Time Delay
The RS-100U has a fi xed time delay of 5 minutes. Lights will remain ON for 5
minutes after the last motion detection.
Coverage Area
The RS-100U has a maximum range of 180
degrees and a coverage area of 600 sq. feet (56
sq, meters). The sensor must have a clear and
unobstructed view of the coverage area. Objects
blocking the sensor's lens may prevent detection
thereby causing the light to turn OFF even though
someone is in the area.
Windows, glass doors, and other transparent barriers will
obstruct the sensor's view and prevent detection.
Call 888.817.0571 for Technical Support
RS-100U
Wall Switch
Occupancy Sensor
with Manual ON/OFF
Lens
Lighted Switch
ON/OFF Button
Santa Clara, CA 95050
12'
(3.7m)
Fig. 1: Sensor Coverage Area
25'
(7.6m)