LEGRAND WattStopper RD-200 Instrucciones De Instalación
LEGRAND WattStopper RD-200 Instrucciones De Instalación

LEGRAND WattStopper RD-200 Instrucciones De Instalación

Sensor de desocupación de pared confi gurable con control manual de encendido/apagado y atenuación de luz

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Please read all instructions before installing
Dimming Wall Switch
with Manual ON/OFF/Dim
Lens
Air Gap Isolation Switch
Lighted Switch
ON/OFF/DIM button
SPECIFICATIONS
Voltage ............................................................... 120VAC, 60Hz
Load (Single Pole Circuit) .......................................25-500 Watt
Compatibility ...................................................Incandescent
Time Delay Adjustment ....................15 seconds to 30 minutes
Light Level Adjustment ....................................... 10 fc to 150 fc
Environment ..................................Residential Indoor use only
Operating Temperature ............... 32° to 131°F (0° to 55°C)
Humidity ...................................... 95% RH, non-condensing
Electrical Supply Wire Requirement
Minimum temperature rating ..........................75°C (167°F)
Tools Needed ......................................... Insulated Screwdriver
DESCRIPTION AND OPERATION
The RD-200 Dimming Wall Switch Vacancy Sensor is designed to replace a
standard light switch or dimmer. It is ideal for living and dining rooms, family
rooms, bedrooms, bathrooms or any other indoor area in a residential space
where occupancy sensor-based manual ON/OFF and dimming control is
desirable.
Like a standard switch, you press the ON/OFF/DIM button to turn the dimmable
light (load) ON and OFF. Unlike a standard switch, the RD-200 automatically turns
OFF the controlled load after the coverage area has been vacant for a period of
time (Time Delay). If motion is detected within 30 seconds after it automatically
turns OFF, the RD-200 automatically turns the load back ON. Like a standard
dimmer, once the lighting load is ON, you can dim it UP or DOWN by pushing and
holding the ON/OFF/DIM button. When you push the ON/OFF/DIM button to turn
the dimmable load ON, the RD-200 recalls the last used dimming level.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation,
it can be adjusted to work as an Occupancy Sensor that turns the controlled load
ON to the last used lighting level automatically upon detecting occupancy in the
area.
Lighted Switch
To help you locate the RD-200 in a dark room, the amber LED illuminates the
ON/OFF/DIM button while the controlled load is OFF. When the controlled load is
ON, the LED is OFF.
The lighted switch ON/OFF/DIM button can be used to manually turn ON and OFF
the lighting load and to dim it UP and DOWN.
To turn the load ON, tap fi rmly on the ON/OFF/DIM button once. The amber LED
turns OFF and the load turns ON to the last used dimming level. The lighting load
may or may not appear to be ON depending on how low the lights were set the
last time they were dimmed.
Once the load has been turned ON, push and hold the ON/OFF/DIM button to
dim the lights UP or DOWN. The RD-200 will cycle the lights UP and DOWN
continuously until the ON/OFF/DIM button is released. To reverse the dimming
direction before a full cycle is completed, momentarily release the ON/OFF/DIM
button, then push and hold it again. This feature will allow you to reach the
desired dimming level quicker.
Call 888.817.0571 for Technical Support
RD-200
Vacancy Sensor
Wire Strippers
Santa Clara, CA 95050

Publicidad

Tabla de contenido
loading

Resumen de contenidos para LEGRAND WattStopper RD-200

  • Página 1 Please read all instructions before installing RD-200 Dimming Wall Switch Vacancy Sensor with Manual ON/OFF/Dim Lens Air Gap Isolation Switch Lighted Switch ON/OFF/DIM button SPECIFICATIONS Voltage ............... 120VAC, 60Hz Load (Single Pole Circuit) ........25-500 Watt Compatibility ...........Incandescent Time Delay Adjustment ....15 seconds to 30 minutes Light Level Adjustment ........
  • Página 2: Operating Modes

    OPERATING MODES There are two operating modes to select from during set up: MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press the ON/OFF/DIM button to turn the load ON. The RD-200 keeps the load ON until no motion is detected for the selected time delay period (adjustable from 15 seconds to 30 minutes).
  • Página 3 4. Wire the sensor. Twist the existing wires Red -> LOAD (power together with the wire leads Black -> HOT (power to dimmable lamp) from circuit box) on the RD-200 sensor as indicated below. Cap them securely using the wire nuts provided (See Fig 4).
  • Página 4: Test Mode

    Adjusting the Light Level This feature is factory set at maximum, so that even the brightest light will not prevent the sensor from turning the load ON when it detects occupancy. If this feature is not needed, leave the light level at maximum, fully clockwise. 1.
  • Página 5: Warranty Information

    WARRANTY INFORMATION Watt Stopper/Legrand warranties its products to be free of defects in materials and workmanship for a period of fi ve (5) years. There are no obligations or...
  • Página 6: Especificaciones

    Por favor leer todas las instrucciones antes de realizar la instalación RD-200 Sensor de Desocupación de pared confi gurable con control manual de ENCENDIDO/APAGADO y Atenuación de Luz Lente Botón de aislamiento de seguridad Botón iluminado de ENCENDIDO/APAGADO/ ATENUACION ESPECIFICACIONES Voltaje ................
  • Página 7: Instalacion Y Cableado

    Modos de Operación Es posible elegir entre dos modos de operación durante la instalación y confi gu- ración del sensor: MODO 1 Sensor de Desocupación (ENCENDIDO/APAGADO manual, APAGADO AUTOMATICO): el usuario debe presionar el botón de ENCENDIDO/APAGADO/ ATENUACION para encender la carga. El RD-200 mantendrá la carga encen- dida hasta que deje de detectar movimiento por un período de tiempo igual al predefi...
  • Página 8: Configuracion & Programacion Del Sensor

    Conecte el RD-200 únicamente a un Circuito Unipolar. El RD-200 no está diseñado para operar en una confi guración tipo “3 vías” (3-way). Si el cableado existente en la caja de conexiones no concuerda con la descripción de un Circuito Unipolar, usted debe consultar con un electricista califi cado. Strip Gage 3.
  • Página 9: Modo De Prueba

    Selección del Modo de Operación Seleccione el Modo de Operación presionando el Botón de Selección de Modos. El LED color ámbar ubicado detrás del botón de ENCENDIDO/APAGADO/ ATENUACION parpadeará en un patrón determinado que le indicará el modo seleccionado: • Un patrón de un solo parpadeo repetido 3 veces, indicará Modo 1 (Operación como Sensor de Desocupación), ENCENDIDO/APAGADO manual, APAGADO automático.
  • Página 10: Remplazando Lamparas

    (5) años. No existen obligaciones o responsabilidades por parte de Watt Stopper / Legrand por daños ocasionados por o en conexión con el uso o desempeño de este producto u otros daños indirectos en materia de pérdida de propiedad, ventas o ganancias, o...

Tabla de contenido