GETTING STARTED
At power up, the EC6000 will run a self test, where the EC6000 motor will sound,
the LED's will cycle five times through a sequence of red, amber & green.
Floating the Coin Tubes
The EC6000 coin tubes should only be filled by inserting coins through the
discriminator.
Any coins that are manually inserted will not be recognised by the EC6000.
Fill Tube using Service Mode
1. Press the Yellow 'Mode' button once.
2. Press 'A' button and start inserting coins through the discriminator.
3. Only coins required for the tubes will be accepted and the acceptance will
stop when the set float level is reached.
4. Press the Yellow 'Mode' button to exit float mode.
Note: MEI recommends that a small number of coins (e.g. 5 of each) be inserted
in each tube prior to leaving the machine.
Page 5 of 10