PowerBoss 030228 Instrucciones De Uso página 13

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
120 Volt AC, 30 Amp Locking
Receptacle
Use a NEMA L5–30 plug with this receptacle. Connect a
3–wire cord set rated for 125 Volt AC loads at 30 Amps to
the plug (Figure 14).
Figure 14 — 120 Volt AC, 30 Amp, Locking Receptacle
3-Wire Cord Set
Use this receptacle to operate 120 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts (3.6 kW) of power
at 30 Amps.The outlet is protected by a 30 Amp
push–to–reset circuit breaker.
8000W Portable Generator
NEMA L5-30
Neutral
120V
Hot
Ground (Green)
13
120 Volt AC, 20 Amp, Duplex
Receptacle
Each receptacle (Figure 15) is protected against overload by
a 20 Amp push–to–reset circuit breaker.
Figure 15 — 120 Volt AC, 20 Amp, Duplex Receptacle
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
PowerBOSS™

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido