OPERATION
OPERATING THE
GENERATOR
CAUTION
Exceeding generator's wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
• See "Don't Overload Generator".
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
• Turn electrical loads OFF and disconnect from generator
before stopping generator.
IMPORTANT: Always unplug the battery float charger
before starting the generator.

Starting the Engine

Disconnect all electrical loads from the generator. Use the
following start instructions:
1.
Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2.
Turn the fuel valve to the "On" position (Figure 5).The
fuel valve handle should be vertical (pointing toward
the ground) for fuel to flow.
Figure 5 — Fuel Valve
Fuel Valve is shown
in "On" position
3.
Set Run/Stop switch to "Run" position (Figure 6).
Figure 6 — Run/Stop Switch
4.
Follow start instructions given in engine owner's manual.
Push and hold the Ignition switch in start position
(Figure 7) until generator starts.To prolong the life of
starter components, DO NOT hold Ignition switch in
start position for more than 15 seconds, and pause for
at least 1 minute between starting atempts.
8000W Portable Generator
Figure 7 — Ignition Switch
NOTE: If engine starts but fails to run, or if unit shuts
down during operation, make sure unit is on a level surface
and check for proper oil level in crankcase.This unit may be
equipped with a low oil protection device. See engine
manual.
• DO NOT touch hot surfaces.
• Allow equipment to cool before touching.
• The generator must be at least 5 feet from structures having
combustible walls and/or other combustible materials.
• Keep at least 3 feet of clearance on all sides of generator for
adequate cooling, maintenance and servicing.
• In the State of California a spark arrester is required by law
(Section 4442 of the California Public Resources Code). Other
states may have similar laws. Federal laws apply on federal
lands. If you equip the muffler with a spark arrester, it must be
maintained in effective working order.
Jump Start Procedure
If generator's starting battery fails, use following instructions
to jump start generator.You can jump start generator using
any 12 Volt automotive or utility style storage battery.
1.
Unscrew fuse holder and remove generator's 10 Amp
in-line fuse (Figure 8).Verify fuse is good or replace
with a known good fuse. Reinstall fuse in fuse holder.
Figure 8 — In-Line Fuse
9
WARNING
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Combustible debris, such as leaves, grass, brush,
ect. can catch fire.
PowerBOSS™