How To Check Nanoe™ X Connection - Panasonic nanoe CZ-CNEXU1 Instrucciones De Instalación

Ocultar thumbs Ver también para nanoe CZ-CNEXU1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
How to Check nanoe™ X Connection
 Check the nanoe™ X connection in the "Detailed settings" of remote controller.
1. Install the indoor unit as described in the installation instructions attached to the indoor unit.
2. Install the remote controller to the indoor unit which is adaptable to the nanoe™ X function.
3. Connect the power wire provided with the earth leakage circuit breaker to the indoor unit and
supply electricity.
4. With the remote control display blinking "Assigning", press
simultaneously for 4 or more seconds to show the "Maintenance func".
5. Select "8. Detailed settings" by using
press
. "Detailed settings" menu is displayed.
6. With using
"Set data". Press
"Unit no.".
7. With using
8. The nanoe™ X operation is normally activated as long as "0000" does not appear under "Set
data". If "0000" appears, the nanoe™ X connection is not recognized.
<In case of "0000">
1. Switch Off the earth leakage circuit breaker.
2. Try to unplug the connector of nanoe™ X kit from the PCB. Then plug it in again.
3. Switch On the power of earth leakage circuit breaker again.
4. Check again the above steps 4 to 8. The nanoe™ X operation is normally activated as long
as "0000" does not appear under "Set data".
If "0000" appears, there is possibly something wrong with the unit.
Contact the dealership you purchased.
/
, select "Unit no.", "Code no." or
with showing "ALL" under
/
, select "9F" under "Code no.".
+
/
and
+
E
7
NGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido