Make sure that the receiver is set to receive the type of coding of the transmitter you wish to memorize: visualize and, if
1
necessary, update parameter n° 8 "type of coding" (see "8.4 Personalization of working parameters "
Channel selection and linking on the transmitter
The built-in receiver can control both the start input and the pedestrian one. By setting the correct value
of the parameter "P009 Selection and linking of radio channels" it is possible to decide which key of the
transmitter will activate each input. If you check on the "working parameters" table you will realize that
the P009 parameter allows you to choose among 16 different combinations. If, for instance, you attribute
value "3" to the parameter P009, all memorized transmitters will activate the start input through CH1 and
the pedestrian input through CH4. Please refer to chapter "8.4 Personalization of working parameters"
in order to select the right combination.
8.4
Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize the one you wish to set (ex. P010)
Confirm! The display shows the set parameter value
Increase or decrease the value until you reach the value you wish to define
Confirm! The display shows again the parameter
Scroll down the parameters until you visualise "----".The control board awaits
further instructions
The automation is now ready to work according to the new working parameters.
8.5
Resetting of default parameters (p.007)
DEA 224RR control board software includes a reset procedure to restore default values (the one
set by the maker) of all settable parameters, see Table 2 Parameters. The value originally set for each
parameter is shown in the "working parameters table". In case you should reset all values and restore
all default values, proceed as follows:
Instructions
The control board is ready to receive instructions
Scroll down the parameters until you visualize P007
Confirm! The control board awaits a further confirmation
Confirm by pressing on the OK button. The procedure starts
All parameters are now set at their original value
Scroll down the parameters until you visualise "----". The control board awaits
further instructions
8.6

Safety devices

DEA 224RR control board allows installers to set up installations that truly comply with European
regulations concerning automated garage doors and gates. More specifically, this control board allows
you to comply with the limits set by the same regulations as to impact forces in case of collision with ob-
stacles. DEA 224RR control board is equipped with a built-in anti-crush safety device that, associated to
the possibility of tuning up the motors' speed, allows you to comply with the limits imposed by the above
mentioned regulations in most installations.
In particular, you can adjust the anti-crush safety device sensitivity by properly setting the value assi-
gned to the following parameters (see also "8.4 Personalization of working parameters "):
• P014 motor 1 f orce i n o pening: f rom 3 0 ( min. f orce, m ax s ensitivity) t o 1 00 ( max f orce, n eutralized s ensitivity)
• P015 motor 1 f orce i n c losing: f rom 3 0 ( min. f orce, m ax s ensitivity) t o 1 00 ( max f orce, n eutralized s ensitivity)
• P016 motor 2 f orce i n o pening: f rom 3 0 ( min. f orce, m ax s ensitivity) t o 1 00 ( max f orce, n eutralized s ensitivity)
• P017 motor 2 f orce i n c losing: f rom 3 0 ( min. f orce, m ax s ensitivity) t o 1 00 ( max f orce, n eutralized s ensitivity)
Operating instructions and warnings

Personalization of working parameters

Function
Function
Display
Display
19
2 2 4 R R