said devices.
• The device must discharge directly outside in a single allocated duct.
• The extracted air flow must be clean (or rather free of grease, soot, chemical and corrosive substances or explosive and
flammable mixtures).
• Never cover the device intake and return to ensure optimal air passage.
• Maximum operating temperature: 45°C.
The appliance must be installed by a professionally qualified electrician.
The electrical system to which the product is connected must be in compliance with applicable
regulations.
An omnipolar switch with a contact opening distance of 3 mm or higher should be provided for
installation, enabling complete disconnection under overvoltage
category III conditions.
Products equipped with single-phase wiring (M) engines ALWAYS
require connection to 220-240V (or only 230V where required)
single-phase lines. Any kind of modification shall be considered as
product tampering and shall nullify the relative warranty.
No specific adjustment is necessary as the devices operate at
nominal frequencies without a preliminary setting.
• The electrical specifications correspond to the ones on the data label A (fig.1).
28
1
A