NOTICE TO INSTALLER: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test/
oil fill plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.
SEE BELOW FOR LIST OF WARNINGS
1. To reduce the risk of electrical shock, a properly grounded receptacle or
control box of grounding type must be installed and protected by a ground
fault circuit interrupter (GFCI) in accordance with the National Electrical
Code and applicable local codes. Never remove ground pin from plug.
2. Make certain that the ground fault interrupter protected receptacle is within
reach of the pump's power supply cord. DO NOT USE AN EXTENSION
CORD. Extension cords that are too long or too light do not deliver sufficient
voltage to the pump motor and could present a safety hazard if the insulation
were to become damaged or the connection end were to fall into a damp or
wet area.
3. Make sure the pump's electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit, sized according to
the National Electrical Code for the current shown on the pump name plate,
is recommended.
4. Testing for ground. As a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory Listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly
connected to your outlet. If they are not, call a qualified, licensed electrician.
5. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS
POWER SOURCE BEFORE HANDLING. If pump is wired direct, de-energize
the circuit at the control box. Grounded pumps are supplied with a 3-prong
grounded plug to help protect you against the possibility of electrical shock.
DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN.
To reduce the risk of electrical shock, a properly grounded receptacle of
grounding type must be installed and protected by a ground fault circuit
interrupter (GFCI) or residual current device (RCD) in accordance with
National Electrical Code and applicable local codes.
6. Installation and servicing of electrical circuits and hardware should only be
performed by a qualified, licensed electrician.
7. Check to be sure your power source is adequate to handle the amperage
requirements of the motor as indicated on the pump or name plate.
MAIL TO: P .O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
QWIK JON
®
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
© Copyright 2017 Zoeller
ULTIMA 202 SYSTEMS
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL. When you see this
symbol on the pump or in the manual, look for one of the
following signal words and be alert to the potential for
personal injury or property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that CAN cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection
to an external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO CAUTIONS AND WARRANTY ON PAGE 2.
Co. All rights reserved.
®
FM2369
Supersedes
Visit our web site:
zoellerpumps.com
MODEL NO. ____________________
DATE CODE: __________________
DATE INSTALLED: _____________
U.S. Patent Nos.
7,203,976; 9,352,327;
8,562,287
Canadian Patent No.
2,512,023
1117
0917