STEP 7
1)
Install the closet bolts at the points marked earlier.
2)
Place the toilet assembly over the closet bolts. Install
the anchoring hardware and tighten in an alternating
pattern. Check for level and shim as required. Be
careful when tightening bolts or nuts against china
to avoid cracking the china.
3)
Install rubber bellows onto the toilet discharge and
grinder tank hub and secure with the worm clamps
provided for stand alone installation. See sketch
in Step 4. For built-in installation, install the rubber
couplings to both the grinder tank and the toilet
discharge and secure to extension pipe with worm
clamps provided. See sketch in Step 5.
4)
Install the water supply line from the existing water
shut-off valve to the toilet water supply connection.
5)
Open the water supply valve and check for leaks.
The toilet tank should fill to the proper level. Adjust
if required.
6)
Plug the pump's power cord into the piggyback switch
receptacle and then plug the piggyback switch into
the GFCI outlet.
7)
Flush the toilet and watch for proper operation. Listen
for the pump to start. The pump unit requires proper
venting in order for toilet to flush. Check for leaks.
8)
Repeat flush cycles to assure proper operation.
9)
Install an elongated toilet seat (supplied by
others).
10)
Install the lid on the toilet tank.
Toilet Installation
GFCI
OUTLET
MAIL TO: P .O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
© Copyright 2017 Zoeller
Co. All rights reserved.
®
10
DISCHARGE
PIPE
WATER
SUPPLY
PUMP UNIT
FLOOR LEVEL TO WITHIN 1/8" (3 mm)
These are the original installation instructions.
VENT PIPE
(PER ALL CODES.
DO NOT USE
MECHANICAL VENT)
AUX. INLET
SK2595