SAFETY INFORMATION
This meter is designed and manufactured according to the safety requirements set out by the
IEC61010-1 standards for electronic test instruments and the hand-hold digital multimeters.
Its design and manufacture is strictly based on the provisions in the CAT III 600V of
IEC61010-1 and the Stipulation of 2-Pollution Grade.
WARNING
To avoid possible electric shock, personal injury, or death, read the following before using
the Meter:
• Use the test leads supplied to ensure operation safety. If required, they must be replaced
with test leads of the same model or class.
• Inspect the test leads before use. Do not use them if insulation is damaged or metal is
exposed. Check the test leads for continuity. Replace damaged test leads before using,
Do not use the Meter if it appears damaged.
• Do not touch the metal tips of the test leads when the meter is connected to the circuit to
be measured.
• When voltage > 60V DC or AC peak, keep your fingers behind the finger guards.
• Verify the Meter's operation by measuring a known voltage before and after using it. Do
not use the Meter if it operates abnormally. Select the highest range if the value scale to
be measured in the manual range is unknown.
• Do not take voltage measurement if the value between the terminals and earth ground
exceeds 600V.
• Disconnect the test leads from the circuit under test before turning the rotary selector to
change functions.
• Disconnect circuit power and discharge all high voltage capacitors before testing
resistance, continuity, diodes, or capacitor.
• Do not store or use the meter in areas exposed to direct sunlight, at high temperature or
with high relative humidity.
• Do not touch live circuit or exposed metal.
MAINTENANCE
• Before opening the rear of the meter, disconnect test leads from all sources of electric
current.
• Use damp cloth and mild detergent to clean the meter; do not use abrasives or solvents.
• Whenever it is likely that safety protection has been impaired, make the Meter inoperative
and secure it against any unintended operation.
• Have the Meter serviced only by qualified service personnel.
INTRODUCTION
This meter 3 3/4 digits with steady operations,fashionable structure and highly reliable
measuring instrument. The Meter uses large scale of integrated circuit with double integrated
A/D converter as its core and has full range overload protection. The meter can perform
measurements of AC current, AC/DC voltage, resistance, capacitance as well as continuity
and diode test.
AUTO POWER OFF
To preserve battery life, the Meter automatically turns off if you do not turn the rotary switch or
press any button for around 15 minutes. The Meter can be activated by pressing SEL button.
REPLACE BATTERY
WARNING
To avoid possible electric shock, disconnect the test leads from the circuit under test before
replace the battery. Use always the same battery type.
Make sure the transformer jaw and the test leads are disconnected from the circuit being
tested before opening the case bottom. Check that the batteries have been installed and the
battery cover has been screwed before use. Replace the batteries as soon as the battery
indicator
appears.
Performs replace battery:
• Disconnect the test leads from live circuit, switch the rotary switch to "OFF" position.
• Remove test leads form input terminals.
• Remove the screw from the battery cover, and separate the battery compartment from the
case bottom. Replace the battery with 3 pcs. of new 1.5V (AAA) batteries.
• Rejoin the case bottom and the battery cover,and reinstall the screw.
ACCESSORIES
• Summary instruction manual: 1 unit
• Test leads: 2 units
• Box: 1 unit
• 1.5V SIZE AAA Battery: 3 units
ENG
ENGLISH
instruction manual:
APAC: MGL GLOBAL SOLUTIONS LTD
info.apac@mgl-intl.com
Flat 4-1, 4/F, No. 35, Section 3 Minquan
East Road. Taipei, Taiwan.
Tel: +886 2-2508-0877
EMEA: MGL EUMAN S.L.
info.emea@mgl-intl.com
Parque Empresarial Argame, 33163
Morcín. Asturias, Spain.
Tel: +34 985-08-18-70
Digital clamp meter
See the full
AMERICAS: MGL AMERICA, LLC.
info.na@mgl-intl.com
US East Coast: 2810 Coliseum Centre
Drive, Ste. 100. Charlotte, North Carolina,
MGL EUMAN, S.L.
28217 USA
Parque Empresarial de Argame,
Tel: +1 833 533-5899
C/Picu Castiellu, Parcelas i-1 a i-4
US West Coast: 760 Challenger Street.
E-33163 Argame, Morcín
Brea, California 92821 USA
Asturias, España, (Spain)
Tel: +1 310-728-6220
www.mgl-intl.com
ENG

Publicidad

loading

Este manual también es adecuado para:

Kpspa20minicbint