Second Section - FOR THE INSTALLER
Connection, starting-up of the appliance and troubleshooting must be carried out by trained and qualified
fitters.
Caution: indoor electric network as well as ambient where the appliance is installed, must strictly comply
with standards and safety regulations in force.
The Manufacturer cannot assume any responsibility for any damage to persons or property
deriving from the non-observance of the above-specified norms.
Place the appliance in the required position and
adjust the feet to level. Remove all protective
films and adhesive labels.
ELECTRICAL CONNECTION
Before connecting the machine,
check to make sure the voltage
outlet of the mains is
the same as the voltage specified
on the data plate of the machine.
A main switch must be installed between the
mains and the machine. This safety measure
also
requires that the minimum distance
between the switch contacts is at least 3 mm
and the
disconnection on all poles according to EN
60204 (VDE 113).
Fuses on the main switch must be 16 A .
The mains must be wired to be able to handle
the current drawn by the machine.The system
must
also be provided with a proper ground lead in
accordance with the existings norms. The
electric
cable must be of the following
type H07RN-F.
For the right choice of the cross section area
refer to the following table:
Cross Section area
mm²
0,75
1
1,5
2,5
The electrical safety of this equipment is only
assured if it is connected as follows.
Total loading
A
< 6
6 - 10
10 - 16
16 - 25
It is necessary to connect the equipment to an
effective ground installation, as specified by the
electrical safety regulations in force.
Chack that this basic requirement is complied
with and, in case of doubt, ask for a careful
check of
the installation by a qualified personal.
In addition, the equipment shall be part of an
equipotential system, the effectiveness of which
should be checked according to the regulations
in force.
The connection should be made at the screw
marked by the respective label located on the
equipment back side (
THE
MACHINE
CONNECTED
EFFECTIVE GROUND CLAMP.
The manufacturer declines any
responsibility for any damages
caused by lack of an effective
ground installation.
25
ENGLISH
).
SHALL
BE
WITH
AN