4. INSTALLATION AND CONNECTION (continued)

4.3 Hydraulic connection

The heat pump comes with two 32 mm/38 mm fittings.
Wrap the threads of the fittings 15 to 20 times around with teflon.
Screw in the two fittings as indicated in the figure below.
Connect the bypass kit (1) and the pipes, following the direction of
circulation indicated in the figure.
See also the diagram on page 8.
Once the device has water running through it, verify that the connection is
watertight. Add teflon if there is a leak.
Water outlet
Water inlet
Fittings
Bypass kit
towards (4) and the pool
from the pool
and the pump (2-3)