Mark MK 1600 LED Manual De Uso página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

button of wireless transmitter, when LCD back light of the two machines flashes twice, then
release button.
2. Machine works under wireless control
After the machine finished heating, press any key of wireless transmitter, machines can start to
work, release the button, the machine stopped will stop work.
Note:
If the wireless control function is set off ( "Wireless Set OFF" on the LCD screen), when
powered again, it will not display"Wireless Set up" page.
When the machine identifies a wireless transmitter, you must wait until the back light of LCD
screen flashes twice, then release the bu tton, because only in this state, it recognizes the wireless
transmitter.
DMX control
After the machine connect the DMX signal, the LCD screen can only display DMX-512 address
settings page, you can modify DMX-512 address codes by pressing the "UP" or "DOWN" bu tton
at this time. DMX control channels as follows:
DMX channel
Channel 1: Fog ( 0-9 OFF, 10-255 ON, the output volume of smoke gradually become larger)
Channel 2: Red
( 0-9 OFF, 10-255 ON, red become ligther)
Channel 3: Green ( 0-9 OFF, 10-255 ON, green become ligther)
Channel 4: Blue
( 0-9 OFF, 10-255 ON, blue become ligther)
Channel 5: Yellow ( 0-9 OFF, 10-255 ON, yellow become ligther)
Channel 6: Color mixing( 0-9 OFF, 10-255 ON, color mixing)
Channel 7: Strobe ( 0-9 OFF, 10-255 ON, LED strobe become faster)
Channel 8: Dimmer ( 0-9 OFF, 10-255 ON, LED dimmer become lighter)
Channel 9: X-axis control (0-255 corresponds to 0-540 degree)
Channel 10: Y-axis control (0-255 corresponds to 0-270 degree )
Routine maintenance and solutions to faults
1.Can not pollute the fluid in order to keep the fluid clean, the cap should be tighten immediately
after adding oil , and regularly clean the filter inside of the oil bottle .
2. After 40 hours of con tinuous use, please use 80% dist illed water and 20% white vinegar mixed
into a detergent to clean the impurities inside the heater.
3. Unscrew the oil cap, remove the suction pipe, and plug in the power, making it spray
continuously 3-4 times in the open area, and then put suction pipe back into the oil bottle to spray
once again until the smoke can be normal.
4. All moving head machines are likely to be blocked, due to frequent oil filter unclean or
long-term use, so regular maintenance can be more long-term use. When you hear the vibration of
the pump more than two minutes but no smoke out, the reasons should be a heater sealed problem.
MK 1600 LED
- 6 -
EN
User Manual/Manual de Uso

Publicidad

Tabla de contenido
loading

Tabla de contenido