Parameters In The Pressure Switch Digital Display - Parker SCPSDi Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.1

Parameters in the pressure switch digital display

Settings of switch outputs in menu
Switching point (SP): the upper pressure limit, at which the
SP1
switching output changes its state.
SP2
SP1 = switching output 1; input pressure value (e.g. 400 bar)
SP2 = switching output 2; input pressure value (e.g. 430 bar)
Reverse switching point (rP): the lower pressure limit, at which
rP1
the switching output changes its state.
rP2
rP1 = Reverse switching point (rP1) of switch output 1;
input as pressure value (e.g. 390 bar)
rP2 = Reverse switching point (rP2) of switch output 2;
Input as pressure value (e.g. 420 bar)
The reverse switching point is always lower than the corre-
sponding switching point.
36

Publicidad

Tabla de contenido
loading

Tabla de contenido