if the installation mode is activated before the issuer has been synchronized least
once, time will be transmitted to the time base of the issuer will operate autono-
mously and have started at 0H00.00s.
*
1.3. PRODUCt COnFIGURatIOn
1.3.1. SETUP in GPS and AFNOR (UTC)
►
Time zone and time difference configuration:
n° SwItCH
1
2
3
4
5
6
7
8
20
1
2
time difference in BCd format
4
8
10
Sign of the time difference
«-» if set to on, «+» if set to oFF
Continuous transmission if set to «on» =tESt modE
(no gPS Synchronization)
Summer/Winter changeover if set to «on»
MEanInG