Technical Data; Returning For Service - DeFelsko PosiTector IRT Manual De Instrucciones

Ocultar thumbs Ver también para PosiTector IRT:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Conforms to: ISO 8502-4, BS7079-B and ASTM D3276
Specifications
Temperature
Range
Laser Pointer
Distance to Spot Ratio (D:S)
Emissivity
Response Time
Spectral Response
Before returning the instrument for service...
1. Install new batteries in the proper alignment as shown within
battery compartment.
2. Examine the surface temperature sensor for dirt or damage.
3. Perform a Hard Reset (pg. 5).
4. If issue is not resolved, Update (pg. 11) your PosiTector
gage body and re-attempt measurements.
IMPORTANT:
If these steps do not resolve the issue and the Gage must be
returned for service, please follow the instructions provided at
www.defelsko.com/service.

Technical Data

Technical Data
Range
–70˚ to 380˚ C
–94˚ to 716˚ F

Returning for Service

Returning for Service
Accuracy
± 1˚C + 1%
@ 23˚ C ambient
Class 2 < 1mW
<500 µs (95% response)
12
Resolution
0.1˚ C
0.1˚ F
5.7:1
Adjustable
2 - 14 µm

Publicidad

Tabla de contenido
loading

Tabla de contenido