DeFelsko PosiTector IRT Manual De Instrucciones página 7

Ocultar thumbs Ver también para PosiTector IRT:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Gage Info
Displays information on the gage body and attached probe.
Trend Chart
Turns the trend chart on. The trend chart can also be turned on by
pressing the Up navigation button from the main screen.
Emissivity
Sets the emissivity ratio for the PosiTector IRT infrared
temperature sensor.
Select Custom to manually adjust the emissivity value or to adjust
to a known temperature. Emissivity is automatically calculated
when adjusting to a temperature. See NOTE below.
Alternatively, use one of the following preset options:
Aluminum (rough) = 0.07
Zinc (Galvanized) = 0.25
Concrete = 0.54
Paint = 0.96
Emissivity
Zinc Galv. 0.25
Steel Ox. 0.95
Al Rough 0.07
Concrete 0.54
Wood 0.95
Paint 0.96
Plastics 0.94
Custom
Exit
NOTE:
Depending on surface treatment, metals such as blasted steel can
have a broad range of emissivity values. Adjusting to a known
temperature (measured by a direct contact surface temperature
probe) on a representative sample will assist in obtaining an
accurate emissivity value.
Sound
Adjusts the volume of built-in speaker (Off, Low, Medium, High).
Plastics = 0.94
Steel (Oxidized) = 0.95
Wood = 0.95
6

Publicidad

Tabla de contenido
loading

Tabla de contenido