TIMING
As a result of the EU65 "Energy label"
and EU66 " Ecodesign regulations is-
sued by the European Commission,
which came into force as from Janua-
ry 1st, 2015 , our products have been
adapted to comply with these new re-
quirements.
All of the models complying with the
energy label requirements, are equip-
ped with new electronics including a
timer device for suction speeds control,
when the air capacity exceeds 650m³/h.
Internal motor models, Internal motor
models, whose air capacity exceeds
650m³/h, have the IV speed temporized
after 5 minutes of operation.
When abovementioned timing elapses,
the motor switches to IIIa speed auto-
matically.
The energy consumption of the applian-
ce in stand – by mode is lower than
0.5W.
OTHER FUNCTIONS
Automatic turn-off
After 4 hours of continuous operation
from the last setting, the appliance turns
off and closes automatically.
Grease filters saturation
After 30 hours of operation, the speed
indicators will all flash simultaneously,
signaling the grease filters saturation.
To reset this function, press the "TI-
MER" key for at least 3 seconds, while
the extractable unit is open.
ADJUSTMENT
The hood self-adjust every 3 comple-
te cycles performed by the extractable
unit. By pressing the "Timer" key 6 times
in a raw (MAX 3 sec. between one push
and the other ) all the leds will flash in
and the hood adjustment will be reset.
The downdraft performs self-adjustment
after the next 3 cycles.
CRUSHPROOF SAFETY DEVICE
If an obstacle obstructs the closure of
the suctioning panel, the closure is
stopped and the panel lifts up.