Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
TIMING
As a result of the EU65 "Energy label"
and EU66 Ecodesign regulations issued
by the European Commission, which
came into force as from January 1st,
2015 , our products have been adapted
to comply with these new requirements.
All of the models complying with the
energy label requirements are equipped
with a timer device that automatically
regulates the suction speed when the
air capacity exceeds 650m³/h.
External motor appliances can only be
combined with external motors that, as
for internal motor versions, are equip-
ped with a timer device regulating
speeds with air capacity higher than
650m³/h, (See instructions detailed in
the external motor section).
External motors with air capacity higher
than 650m³/h, both at IV and III speed,
are automatically temporized as fol-
lows: from IV speed it is switched au-
tomatically to III speed after 6 minutes
of operation.
If the appliance is set at III speed, it is
switched automatically to II speed after
7 minutes of operation. Nevertheless,
changing the speed set is always pos-
sible.
The energy consumption of the ap-
pliance in stand - by mode is lower than
0.5W.

OTHER FUNCTIONS

Automatic turn-off
After 4 hours of continuous operation
from the last setting, the appliance turns
off and closes automatically.
Grease filters saturation
After 30 hours of operation, the speed
indicators will all flash simultaneously,
signaling the grease filters saturation,
To reset this function, press the "TI-
MER" key for at least 3 seconds, while
the extractable unit is open.
ADJUSTMENT
The hood self-adjust every 3 comple-
te cycles performed by the extractable
unit.
By pressing the "Timer" key 6 times in a
raw (MAX 3 sec. between one push and
the other) all the leds will flash in and
the hood adjustment will be reset .
The downdraft performs self-adjustment
after the next 3 cycles.
CRUSH - PROOF SAFETY DEVICE
If an obstacle obstructs the closure of
the suctioning panel, the closure is
stopped and the panel lifts up.
40