Zoeller 292-0002 Instrucciones De Instalación página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Manufacturer warrants, to the purchaser and subse uent owner during the
warranty period, every new product to be free from defects in material and
wor manship under normal use and service, when properly used and maintained,
for a period of one year from date of purchase by the end user, or 18 months
from date of original manufacture of the product, whichever comes rst. arts
that fail within the warranty period, one year from date of purchase by the
end user, or 18 months from the date of original manufacture of the product,
whichever comes rst, that inspections determine to be defective in material or
wor manship, will be repaired, replaced or remanufactured at Manufacturer s
option, provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No allowance
will be made for shipping charges, damages, labor or other charges that may
occur due to product failure, repair or replacement.
his warranty does not apply to and there shall be no warranty for any material
or product that has been disassembled without prior approval of Manufacturer,
subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable
act of nature that has not been installed, operated or maintained in accordance
with Manufacturer s installation instructions that has been e posed to outside
substances including but not limited to the following sand, gravel, cement, mud,
tar, hydrocarbons, hydrocarbon derivatives oil, gasoline, solvents, etc. , or other
abrasive or corrosive substances, wash towels or feminine sanitary products,
In those instances where damages are incurred as a result of an alleged pump failure,
the Homeowner must retain possession of the pump for investigation purposes.
1. DO read all installation material with the unit.
2. DO inspect unit for any visible damage caused by shipping. Contact dealer
if unit appears to be damaged.
3. DO remove all debris from the basin.
hard, level surface beneath it. DO NOT install on sand, gravel or dirt.
4. DO be sure that the area is large enough to allow proper clearance for the
level control switch es to operate properly.
5. DO Always Disconnect Pump From Power Source Before Handling.
DO always connect to a separately protected and properly grounded circuit.
DO NOT ever cut, splice, or damage power cord Only splice in a watertight
junction bo .
DO NOT carry or lift pump by its power cord.
DO NOT use an e tension cord.
6. DO install a chec valve and a union in the discharge line.
DO NOT use a discharge pipe smaller than the pump discharge.
CONDITION
.
ump will not start or run.
Motor overheats and trips
.
overload or blows fuse.
C.
ump starts and stops too often.
D.
ump will not shut off.
ump operates but delivers little
.
or no water.
Drop in head and/or capacity
F.
after a period of use.
.
an or ttings lea .
If the above checklist does not reveal the problem, consult the Product Support Department. Do not attempt to service or otherwise disassemble
pump. Service must be peformed by a Zoeller Authorized Service Station. Visit www.zoeller.com for a complete list of service stations.
LIMITED WARRANTY
DO'S & DON'T'S FOR INSTALLING UNIT
e sure that the pump will have a
SERVICE CHECKLIST
COMMON CAUSES
hec fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically, motor
or wiring shorted. Float assembly held down. Switch, damaged or out of adjustment.
Incorrect voltage, negative head discharge open lower than normal impeller or seal bound mechanically, motor shorted.
Float switch tether length too short, chec valve stuc open, or none installed in long distance line, overload open, bidding,
sump pit too small.
Debris under oat assembly, oat bound by basin sides or other, switch, damaged or out of adjustment.
Chec inlet, strainer housing, discharge pipe, and vent holes for obstructions. Discharge head e ceeds pump capacity.
ow or incorrect voltage. Incoming water containing air or causing air to enter pumping chamber. Incorrect motor rotation.
3 phase pumps only
Increased pipe friction, clogged line or chec valve. brasive material and adverse chemicals could possibly deteriorate
impeller and pump housing. Chec line. emove base and inspect.
Carefully tighten pipe joints use pipe dope and screws. Chec gas et location, tighten lid evenly. Do not over tighten
ttings or screws.
© Copyright 2015 Zoeller
etc. in all pumping applications. he warranty set out in the paragraph above is
in lieu of all other warranties e pressed or implied and we do not authorize any
representative or other person to assume for us any other liability in connection
with our products.
ontact Manufacturer at, 3649 ane un oad, ouisville, entuc y 40211,
ttention
ustomer Support Department to obtain any needed repair or
replacement of part s or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED
OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR
A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED
TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty, so
the above limitation may not apply to you. Some states do not allow the e clusion
or limitation of incidental or conse uential damages, so the above limitation or
e clusion may not apply to you.
his warranty gives you speci c legal rights and you may also have other rights
which vary from state to state.
7. DO NOT utilize this unit for pumping gasoline or other hazardous li uids.
8. DO test pump immediately after installation to be sure the system is
wor ing properly.
9. DO review all applicable governing codes and verify that the installation
conforms to each of them.
10. DO consult manufacturer for clari cations or uestions.
11. DO consider a two pump system with an alarm where an installation may become
overloaded or primary pump failure would result in property damages.
12. DO consider a D.C. ac up System where a sump or dewatering pump is
necessary for the prevention of property damages from ooding due to .C.
power disruptions, mechanical or electrical problems or system overloading.
13. DO inspect and test system for proper operations at least every 3 months.
®