17. CONNECTIONS
17.1 XW30LH
Supply: 120Vac or 24Vac: connect to terminals 11-12
The light relay can be also 16(5)A according to the model
17.2 XW30LRH
Model at 120Vac: connect to terminals 8-9
18. DEFAULT SETTING VALUES
Label Name
Set Set point
rtC* Real time clock menu
Hy Differential
LS Minimum set point
US Maximum set point
ot Thermostat probe calibration
P2P Evaporator probe presence
oE Evaporator probe calibration
P3P Third probe presence
o3 Third probe calibration
Fourth probe presence (only for
P4P
XW30LH)
Fourth probe calibration (only for
o4
XW30LH)
odS Outputs delay at start up
AC Anti-short cycle delay
Ac1 Second compressor start delay
rtr P1-P2 percentage for regulation
P1-P2 percentage for regulation
CCt Continuous cycle duration
CCS Set point for continuous cycle
Set point for continuous cycle
Con Compressor ON time with faulty probe
Compressor ON time with faulty probe
CoF Compressor OFF time with faulty probe
Compressor OFF time with faulty probe
CF Temperature measurement unit
Temperature measurement unit
rES Resolution
Resolution
Lod Probe displayed
Probe displayed
dLy Display temperature delay
Display temperature delay
dtr P1-P2 percentage for display
P1-P2 percentage for display
EdF* Kind of interval for defrost
Kind of interval for defrost
dFP Probe selection for defrost termination
Probe selection for defrost termination
dtE Defrost termination temperature
Defrost termination temperature
idF Interval between defrost cycles
Interval between defrost cycles
MdF (Maximum) length for defrost
(Maximum) length for defrost
dFd Displaying during defrost
dAd MAX display delay after defrost
MAX display delay after defrost
Fnc Fan operating mode
Fnd Fan delay after defrost
Differential of temperature for forced
FCt
activation of fans
FSt Fan stop temperature
Fon Fan on time with compressor off
FoF Fan off time with compressor off
FAP Probe selection for fan management
ACH Kind of action for auxiliary relay
SAA Set Point for auxiliary relay
SHy Differential for auxiliary relay
ArP Probe selection for auxiliary relay
Sdd Auxiliary relay operating during defrost
ALP Alarm probe selection
ALC Temperat. alarms configuration
ALU MAXIMUM temperature alarm
ALL Minimum temperature alarm
AFH Differential for temperat. alarm recovery
ALd Temperature alarm delay
1592027560 XW30LH-XW30LRH GB r1.0 14.02.2014.doc
Range
°C/°F
LS to US
-5.0
-
-
[0.1 to 25.5°C]
2.0
[1 to 45°F]
[-55°C to SET]
-50.0
[-67°F to SET]
[SET to 150°C]
110
[SET to 302°F]
[-12 to 12°C]
0.0
[-21 to 21°F]
n=not present; Y=present
Y
[-12 to 12°C]
0.0
[-21 to 21°F]
n=not present; Y=present
n
[-12 to 12°C]
0
0
[-21 to 21°F]
n=not present; Y=present
n=not present; Y=present
n
n
[-12 to 12°C]
0
0
[-21 to 21°F]
[-21 to 21°F]
0 to 255 min
0 to 255 min
0
0
0 to 50 min
0 to 50 min
1
1
0 to 255 sec
0 to 255 sec
5
5
0 to 100 (100=P1 , 0=P2)
0 to 100 (100=P1 , 0=P2)
100
100
0.0 to 24h00min
0.0 to 24h00min
0.0
0.0
[-55.0 to 150.0°C]
[-55.0 to 150.0°C]
-5
-5
[-67 to 302°F]
[-67 to 302°F]
0 to 255 min
0 to 255 min
15
15
0 to 255 min
0 to 255 min
30
30
°C to °F
°C to °F
°C
°C
in=integer; dE= dec.point
in=integer; dE= dec.point
dE
dE
P1; P2
P1; P2
P1
P1
0.0 to 20min00sec (10 sec)
0.0 to 20min00sec (10 sec)
0.0
0.0
1 to 99
1 to 99
50
rtC; in
rtC; in
in
nP; P1; P2; P3; P4
nP; P1; P2; P3; P4
P2
P2
-50 to 50°C
-50 to 50°C
8
1 to 120 hours
6
0 to 255 min
30
rt; it; SEt; DEF
it
0 to 255 min
30
C-n; o-n; C-y; o-Y
o-y
0 to 255 min
0
0 yo 50°C
0
[-50 to 50°C]
40
[-55 to 122°F]
0 to 15 min
0
0 to 15 min
0
nP; P1; P2; P3; P4
P2
CL; Ht
cL
[-55.0 to 150°C]
0,0
[-67 to 302°F]
[0.1 to 25.5°C]
2,0
[1 to 45°F]
nP; P1; P2; P3; P4
nP
n(0); Y(1)
n
nP; P1; P2; P3; P4
P1
rE= related to set;
Ab
Ab = absolute
[SET to 150.0°C]
110,0
[SET to 302°F]
[-55.0°C to SET]
-50,0
[-67°F to SET]
[0.1 to 25.5°C]
2,0
[1 to 45°F]
0 to 255 min
15
XW30LH – XW30LRH
Label Name
dAo Delay of temperature alarm at start up
AP2 Probe for temperat. alarm of condenser
AL2 Condenser for low temperat. alarm
AU2 Condenser for high temperat. alarm
AH2 Differ. for condenser temp. alar. recovery
Ad2 Condenser temperature alarm delay
dA2 Delay of cond. temper. alarm at start up
Compr. off for condenser low
bLL
temperature alarm
Compr. off for condenser high
AC2
temperature alarm
tbA Alarm relay disabling
oA1 Light relay configuration
AoP Alarm relay polarity (oA1=ALr)
i1P Digital input polarity
Level
i1F Digital input 1 configuration
- - -
did Digital input alarm delay
Pr1
i2P Digital input polarity
Pr1
i2F Digital input configuration
Pr2
d2d Digital input alarm delay
nPS Number of activation of pressure switch
Number of activation of pressure switch
Pr2
Compress and fan status when open
Compress and fan status when open
odc
Pr1
door
rrd Regulation restart with door open alarm
Regulation restart with door open alarm
Pr1
HES Differential for Energy Saving
HES Differential for Energy Saving
Pr2
Hur* Current hour
Hur* Current hour
Pr2
Min* Current minute
Min* Current minute
Pr2
Pr2
dAY* Current day
dAY* Current day
Hd1* First weekly holiday
Hd1* First weekly holiday
Pr2
Pr2
Hd2* Second weekly holiday
Hd2* Second weekly holiday
Energy Saving cycle start during
Energy Saving cycle start during
ILE*
ILE*
Pr2
Pr2
workdays
workdays
Energy Saving cycle length during
Energy Saving cycle length during
Pr2
Pr2
dLE*
dLE*
workdays
workdays
Pr1
Pr1
ISE* Energy Saving cycle start on holidays
ISE* Energy Saving cycle start on holidays
Pr2
Pr2
dSE* Energy Saving cycle length on holidays
dSE* Energy Saving cycle length on holidays
Pr2
Pr2
Ld1* 1
Ld1* 1
workdays defrost start
workdays defrost start
workdays defrost start
st
st
st
st
Pr2
Pr2
Ld2* 2
Ld2* 2
nd
nd
workdays defrost start
Pr2
Pr2
Ld3*
Ld3* 3
rd
workdays defrost start
Ld4* 4
th
workdays defrost start
Pr2
Pr2
Ld5* 5
th
workdays defrost start
Pr2
Pr2
Ld6* 6
th
workdays defrost start
Pr2
Pr2
Sd1* 1
st
holiday defrost start
Pr1
Pr1
Sd2* 2
nd
holiday defrost start
Pr2
Pr2
Sd3* 3
rd
holiday defrost start
Pr2
Pr2
Sd4* 4
th
holiday defrost start
Pr2
Sd5* 5
th
holiday defrost start
Pr2
Sd6* 6
th
holiday defrost start
Pr2
Pr2
LoC Keyboard lock timer
Pr1
Adr Serial address
Pr1
PbC Kind of probe
Pr1
onF on/off key enabling
Pr2
dP1 Room probe display
Pr2
dP2 Evaporator probe display
Pr1
dP3 Third probe display
Pr1
dP4 Fourth probe display
Pr2
rSE Real set
rEL Software release
Pr1
Ptb Map code
* Only for model with real time clock
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr2
Pr2
Range
°C/°F
0.0 to 23h50min
1,3
nP; P1; P2; P3; P4
nP
[-55 to 150°C]
-40
[-67 to 302°F]
[-55 to 150°C]
110
[-67 to 302°F]
[0.1°C to 25.5°C]
5
[1°F to 45°F]
0 to 254 min; 255=nU
15
0.0 to 23h50min
1,3
n(0); Y(1)
n
n(0); Y(1)
n
n(0); Y(1)
y
ALr = alarm; dEF = do not select
it; Lig =Light; AUS =AUX;
onF=always on; Fan= do not
Lig
select it; db = neutral zone; cP2
= second compressor; dF2 = do
not select it; HES = night blind
oP; cL
cL
oP=opening; CL=closing
cL
EAL, bAL, PAL, dor; dEF; Htr,
dor
AUS
AUS
0 to 255 min
0 to 255 min
15
oP=opening; CL=closing
oP=opening; CL=closing
cL
EAL, bAL, PAL, dor; dEF; Htr,
EAL, bAL, PAL, dor; dEF; Htr,
EAL
AUS
AUS
0 to 255 min
0 to 255 min
5
0 to 15
0 to 15
15
F-c
no; Fan; CPr; F_C
no; Fan; CPr; F_C
y
n(0); Y(1)
n(0); Y(1)
[-30 to 30°C]
[-30 to 30°C]
0
[-54 to 54°F]
[-54 to 54°F]
0 to 23
0 to 23
-
0 to 59
0 to 59
-
Sun to SAt
Sun to SAt
-
Sun to SAt; nu
Sun to SAt; nu
nu
nu
Sun to SAt; nu
nu
0.0 to 23h50min
0
0.0 to 24h00min
0
0.0 to 23h50min
0.0 to 23h50min
0
0
0.0 to 24h00min
0.0 to 24h00min
0
0
0.0 to 23h50min; nu
6.0
0.0 to 23h50min; nu
13.0
0.0 to 23h50min; nu
21.0
0.0 to 23h50min; nu
0.0
0.0 to 23h50min; nu
0.0
0.0 to 23h50min; nu
0.0
0.0 to 23h50min; nu
6.0
0.0 to 23h50min; nu
13.0
0.0 to 23h50min; nu
21.0
0.0 to 23h50min; nu
0.0
0.0 to 23h50min; nu
0.0
0.0 to 23h50min; nu
0.0
nu; 10 to 255 sec
60
1 to 247
1
PtC; ntC
ntc
nu, oFF; ES
oFF
Read Only
-
Read Only
-
Read Only
-
Read Only
-
actual set
-
Read Only
1.8
Read Only
Level
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr1
Pr1
Pr1
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
rtc
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
Pr2
5/5