2.1
INFORMATION ON THE GAS-HEATED FRY-TOPS
This booklet applies to our Fry-Tops type A
Category II (Natural Gas and L.P.G.). See table
1.1 and 2.5. The plate according to EN 437
and EN 203 part 1 standards is under the
bottom edge of the instrument panel.
2.2
LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE OBSERVED
The following regulations must be observed during installation:
- Current accident and fire regulations.
- The regulations of the gas supply company, which has to issue an authorization before installation.
- "Gas system installation" standards.
- Health regulations.
2.3
PLACE OF INSTALLATION
- The unit should be installed in a room with adequate ventilation. This unit requires a draft of at least 2 m
(Thermal Capacity).
- Install the unit in compliance with the safety regulations UNI - CIG 8723, law No. 46 dated 5-3-'90 and Italian Ministerial
Decree D.M. No.74 dated 12.04.96.
2.4
POSITIONING
- The various units may be installed separately or combined with other units in our range.
- This unit is not suitable for encasing.
- The distance from the side walls must be at least 10 cm.; should the distance be less or the material of the walls or floor be
flammable, it is vital to install thermal insulation.
2.5
TABLE II: GAS TECHNICAL DATA, PRESSURE, BURNER NOZZLES, PILOT AND IDLE SCREW
(FOR ALL GFT45 BURNERS)
Nation
Cat.
and
Nozzle
category
ENG, ICEL, DENIM,
FIN, SWED, PORT,
2H
GREECE, IRELAND
NETHERLANDS
2L
ICEL,
DENMARK,
3B/P
FINLAND,
SWEDEND
IRELAND
PORTUGAL
3+
ENGLAND
GREECE
NORWAY
3P
LUXEMBURG
3P
LUXEMBURG
3P
NETHERLAND
V
Cat.
P n
Cat.
P n
Qn
(Hi)
T ype
Gas pressure
of
upstream
gas
mbar
Ø mm. Type
Nom. Min. Max.
MARKED
G20
20
17
25
G25
25
20
30
G30*
29
25
35
G31
G30*
29
20
35
G31
37
25
45
G31
30
20
35
145 / 250 K
G31
37
25
45
G31
50
42,5
57,5
130 / 250 K
Hz
IT-GR-GB-ES-IE
PT
II2H3+
II2H3+
20,29/37
20,29/37
LU
IS-DK-FI-SE
II2E3P
II2H3B/P
20,37,50
20,29
G20
kW
G25
BURNER
BY-P ASS
(23 S)
R.d.A.
Ø mm.
"targhet"
X mm.
MARKED
MARKED
205 L
TA
120 R
215 L
23
120 R
145 L
TA
120
145 L
TA
120
23
120
145 L
TA
120
23
105
- 13 -
Mod.
Matr.N°
kW
FR-BE
NL
II2E+3+
II2L3P
20/25,29/37
25,30,50
AT-CH
DE
II2H3B/P
II2ELL3B/P
20,50
20,20,50
m
3
/h
G30
m
3
/h
G31
PILOT
Gas pressure
Nominal
at nozzle
Thermal
with 24ST
kW (1)
Max.
Min.
100%
mbar
mbar
36
18,8
3,8
8,0
36
23,2
4,1
8,0
19
28,8
7,3
8,0
19
28,8
7,3
8,0
36,4
9,2
19
29,6
6,2
8,0
19
36,4
9,2
8,0
19
49,4
10,1
8,0
Type
tipo
mbar
mbar
NO
I3P
30
Kg/h
Kg/h
3
/h • kW T.C.
Gas
consumption
15°C
P.T.
l/h
g/h
Min.
3,55
847
-
3,30
985
-
3,9
248
631
287
545
3,9
248
631
327
621
3,6
327
621
3,9
327
621
3,8
327
621
GB