GAS COMPONENT CONNECTION CHECKS
3. Make sure that the igniter pin and thermocouple are correctly positioned.
- The igniter pin should be pointed at the thermocouple.
- The thermocouple should be positioned 5mm away from the burn tube.
Thermocouple
Wire
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
18
Igniter
Valve
Igniter Box
Thermocouple Wire
Valve
Thermocouple
Wire should
be in line
with valve