ESQUEMA DE INSTALACIÓN.
INSTALLATION DIAGRAM.
PLACA SECUNDARIA
SECONDARY PANEL
T-810
SW
1 2 3
4
T-810
SW
1 2 3
4
(*) EN MODULOS DE COMPLEMENTO
CONECTAR EL COMUN DE EMBARRADO
AL BORNE VO DEL MODULO P-LUZ
O BIEN AL COMUN DE EMBARRADO
DEL MODULO DE MANDO
(*) FOR COMPLEMENTARY MODULS,
CONNECT COMMON WIRE TO THE
TERMINAL VO P-LUZ MODULE OR
TO THE CONTROL MODULE'S
PUSH-BUTTON COMMON WIRE.
SECCIONES (HASTA 100m.)
0.5mm
2
1.0mm
2
LLamada zumbador.
PE-91 ACCESS
1
2
3
4
5
6
7
8
9
C
0
A-154
PLACA PRINCIPAL
MAIN PANEL
PE-91 ACCESS
1
2
3
4
5
6
7
8
9
C
0
A-490/2
A-490/1
Buzzer call.
The system operates the door-release when the 4 digit number keyed in is the same as
one recorded.
- The total number of differents codes that can be recorded are three for normal opening
and one to open and activate the panic code.
- The factory recorded codes are: 1111, 2222, 3333 and 4444.
- To key in the code press the keys in the correct sequence, simultaneously a bleep will
confirm that each key is pressed. If the code is correct, the green led lights and door release
mechanism is activated for about four seconds.
If the time between two keys being pressed exceeds 4 seconds, the system reverts to
the initial state and you must begin again.
if a mistake is made keying in the code, press the delete key C, and start again.
If the panic code is keyed in, first the green led will light and the door will open as usual,
secondly a relay is activated for 1 minute, which can be connected to what you want
(characteristics: 120 Vac-0'5 A, 24Vdc-1 A). If the panic code coincides with one of the
other three, the relay will not be activated.
- If the code keyed in is incorrect, the red led lights for four seconds and the door panel
shuts off for this time. After this, the system returns to the initial rest state.
If five consecutive incorrect codes are keyed in, the red led lights and the panel shuts
off for 1 minute. After this the system returns to the initial rest state.
- If there is a power failure, the codes are not deleted.
- It is possible to activate a relay (A1, A2 terminals, characteristics: 120 Vac-0'5 A,
24Vdc-1 A) if the panel is opened, this is called TAMPER. It consists of connecting a wire
between terminal TP and an earth point (-), ensuring that if the panel is pulled out this wire
disconnects. Dip4 must also be placed in the down position.
Access control operation.