Technical Data; Preliminary Checks - DITEC Obbi 3BH Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1. TECHNICAL DATA

Power supply
Absorption
Motor power
Geared motor torque
Max. stroke
Stroke time
Intermittence
Temperature
Degree of protection
Wing dimension
m = door width
kg = door weight
Reccomended
dimensions
Limit
dimensions
2.
REFERENCE TO ILLUSTRATIONS
2.1
Standard installation references (fig. 1)
ATTENTION: The given operating and performance features can only be guaranteed with the use of
DITEC accessories and safety devices.
[1]
Radio (BixLP2)
[2]
Flashing light (LampH)
[3]
Key selector (Lab55)
[4]
Connect power supply to a type-approved omnipolar switch with a contact opening gap of no less
that 3 mm (not supplied by us)
2.2
Geared motor reference (fig. 2-4)
[9]
Release
[10] Housing
[11] Draft tube
3.
INSTALLATION
3.1

Preliminary checks

Check that the structure is sufficiently sturdy and that the hinge pivots are properly lubricated. Provide an opening
and closing stop.
Geared motor installation
Unless otherwise specified, all measurements are expressed in millimetres.
3.2 Check the mounting dimensions (fig. 3) as a function of the distance between the wing hinge pivot and the
edge of pillar [C] and of the desired opening angle [D].
3.3 The geared motor is normally supplied in the right-handed version. To convert it to the left-handed version,
proceed as follows (see from Figs. 6 to 10):
-
Loosen the motor clamping screws (Fig. 6).
-
Remove the motor and the reduction gear plug, and slide out the motor cable (Fig. 7).
-
Rotate the reduction gear by 180 degrees (Fig. 8).
-
With the reduction gear in this position, fit in the motor and the plug and route the cable in (Fig. 9).
Attention: Take care to mount the motor so that the cable comes to be on the opposite side of the
release.
-
Fit in and secure the motor clamping screws (Fig. 10).
3.4 Secure the tail bracket [14] (Fig. 4) according to dimensions [A] and [B] (shown in Fig. 3) selected as a function
of the desired opening angle [D]. The tail bracket is provided with holes to facilitate mounting (fig. 5).
Note: The installation measurements given in the table in Figure 3 permit to select the values for [A] and [B]
according to the desired opening angle and with reference to existing room and spaces. Compliance with the
measurement given in the table is recommended, modifying the brackets provided, if so required.
In order to ensure smooth gate movement, check that measurements [A] and [B] are the same. Increasing [A]
reduces the coming up speed during opening. Increasing [B] diminishes the coming up speed during closing
and improves burglar-proofing. Reducing [B] increases the extent of gate opening. Measurements [A] and [B]
must in any case be compatible with the useful travel of the piston so that; if [A] is increased, [B] must be
diminished and vice versa.
Obbi 3BH
24 V
3 A
24 W
1500 N
350 mm
25 s / 90°
S2= 30 min / S3= 50%
-15° C / +50° C
IP54
m
5.0
4.0
3.0
2.0
1.0
100
300
[5] Right geared motor (Obbi 3BH)
[6] Left geared motor (Obbi 3BH)
[7] Photocells (Lab20)
[12] Tube cover
[13] Closing plug
[14] Teil bracket
11
kg
500
[8] Electric board
[15] Head bracket
DITEC S.P.A - IP1639 31/03/2000 Obbi 3BH

Publicidad

Tabla de contenido
loading

Tabla de contenido