Connecting The Directional Power Sensor (Dps); Connecting The Wideband Power Sensor (Wps) - BIRD 5000-XT Libro De Instrucciones

Medidor de potencia digital
Ocultar thumbs Ver también para 5000-XT:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Digital Power Meter Model 5000-XT

Connecting the Directional Power Sensor (DPS)

RF voltage may be present in RF element socket. Keep element in socket
1. Do one of the following:
Models 5010, 5010B:
Connect the Bird DPS to the "Sensor" serial port on the DPM using the
sensor cable provided.
Model 5014:
Connect the Bird DPS to the "Sensor" USB port on the DPM using the
sensor cable provided.
2. Connect the DPS to the RF line so that the arrow on the sensor points
towards the load.
Note: The arrow on the forward element should point towards
the load.
Note: The arrow on the reflected element should point towards
the source.
Note: Both elements must be either APM/DPM or 43 types, do
not mix elements.
3. Set the power on the DPM to the forward element's power rating.
Figure 4
DPS Element Orientation

Connecting the Wideband Power Sensor (WPS)

1. Do one of the following:
Models 5012, 5012B, 5016, 5016B, 5017, 5017B, 5018, 5018B, 5019,
and 5019B:
Connect the Bird WPS to the "Sensor" serial port on the DPM using the
sensor cable provided.
Models 5012D, 5016D, 5017D, 5018D, and 5019D:
Connect the Bird WPS to the "Sensor" USB port on the DPM using the
sensor cable provided.
2. Connect the WPS to the RF line so that the arrow on the sensor points
towards the load.
8