Digital Power Meter Model 5000-XT
Uncertainty
Match Measurement:
Measurement Range
Return Loss
Rho (
VSWR
Uncertainty
Settling Time, Max
Impedance, Nominal
Insertion Loss, Max
Input VSWR, Max.
Directivity, Typical
RF Connectors
Power Supply
Mechanical Shock and
Vibration
CE
Temp, Operating
Temp, Storage
Humidity, Max
Altitude, Max
Dimensions, Nominal
Weight, Nominal
*. Exact value depends on element selected
†. Above 35 °C or below 15 °C add 2%
56
± 8% of full-scale peak envelope power (95%
†
c.l.)
0 to 20 dB
ρ
0.1 to 1
)
1.22 to 99.99
Calculated from forward and reflected
uncertainty.
Twice the Avg Power Uncertainty
2.5 seconds
50 ohms
0.05 dB up to 1 GHz
1.05:1 up to 1 GHz
*
30 dB
QC Type, N(F) normally supplied
From host instrument via cable
In accordance with MIL-T-28800D Class 3
CE compliant. Refer to DOC for specific
standards.
–10 to +50 °C (+14 to +122 °F)
–40 to +75 °C (–40 to +167 °F)
95% (non-condensing)
3,000 m (10,000 ft.)
2.5" x 5.0" x 2.0"
(59 x 127 x 51 mm)
1.25 lb. (0.6 kg)