The device is now waiting for a command which specifies the type of receiver coding
to be used for the Administrator PIN just typed in:
- Press 1 for the Rolling-code receivers
- Press 2 for the ARC receivers
- Press 3 for the Fixed-code receivers
TO MEMORISE ADMINISTRATOR PIN IN THE RECEIVER
After programming the PINs as desired, it is necessary to store them in the receiver.
When the receiver is waiting for a code to be stored, enter the PIN followed by #,
IRI. KPAD will send the code to be stored in the receiver.
More than one receiver can be used, also with a different decoding, and in the event
of multi-channel receivers, various codes can be matched to various channels.
In the event of especially complex installations, it is advisable to make and carefully
keep a diagram of the various receivers used, as well as their functions and related
IRI.KPAD PINS matched to it.
MENU 3
See paragraph on Advanced Functions
MENU 4 (PIN ERASING)
After typing key 4, the erasing phase of the code is entered, indicated by 2 beeps
followed by an interval.
- Type in the PIN to be erased and press #. Three beeps, followed by an interval,
confirm the operation.
MENU 5
See paragraph on Advanced Functions
MENU 6 (OPERATION CONFIGURATION)
Through the Menu the following is possible:
1) Activate or deactivate the buzzer.
2) Switch the back light on and off.
3) Enable or disable keypad activation by pressing the asterisk (*) key. This only
allows the asterisk key to activate the IRI.KPAD, again.
4) Enable or disable the first digit entered as re-activation of the device and first code
entered. This will not require pressing again for re-activation before entering the code.
5) Enable or disable the system lock for 3 minutes after 5 wrong codes are entered,
for greater security against attempts to force the code. Factory configuration includes
functions 1-2 active and 3-4-5 disabled. After typing key 6, the password is required
to have access to advanced functions. The password to have access to the advanced
functions is 654321 and it is not customizable.
Press 6, two beeps are heard, press 654321, press #, three beeps are heard followed
by an interval, one of the sequences are required by the device as follows in menu 6.