1500000006_Anleitung_alle RI Sprachen 2012
SCOPE OF USE
The pump action pipe unblocker is designed for unblocking waste pipes and may not be used
for any other purpose. Deposits or hair, fat or similar are removed in an environmentally friendly
manner by the use of compressed air and without the need for chemicals.
This product may only be used for the purpose described above. Use of the product for any
other purpose can lead to damage or injury.
The pump action pipe unblocker is designed for household use only and may not be used for
commercial or industrial purposes.
The device may not be used in modified form.
The device's operating temperature range is between approx. +15° C and +50° C.
Exposure to sunlight can cause plastic to become brittle. For this reason the product life of the
pump unblocker is restricted to 5 years once the product packaging has been opened. Always
store the pipe unblocker in a dark cool place.
It is essential that you read the safety instructions before using the device and that you follow
these carefully.
Keep this user guide in a safe place and pass it to anyone who uses the device.
ASSEMBLY
For technical reasons the pump handle is not factory fitted.
Proceed as follows to fit the pump handle:
- Remove the bolt from the pump handle
using a Phillips screwdriver.
- Slide the pump handle on to the pump
cylinder.
- Rotate the pump handle on the pump
cylinder to line up the holes in the pump
handle with the holes in the pump
cylinder are in line.
- Use a Phillips screwdriver to fix the pump
handle in place with the bolt and nut.
USING THE PUMP ACTION PIPE UNBLOCKER
Before using the device select the rubber adapter that best fits the waste pipe you wish to
unblock and fit this to the device's nozzle.
Toilet adapter
Shower waste adapter
Basin / Sink adapter
large disc-type adapter, approx. 20 cm ø
small disc-type adapter, approx. 11 cm ø
large / small rubber adapters, approx 5/6 cm ø
9
28.06.2012
16:32 Uhr
Seite