Descargar Imprimir esta página

Kohler K-1114-LH Diagrama De Instalación página 2

Bañera de hidromasaje

Publicidad

Idiomas disponibles

Idiomas disponibles

21"
(53.3 cm)
3-3/4"
(9.5 cm)
11-1/16" (28.1 cm)
1-1/4"
(3.2 cm)
3-1/2"
(8.9 cm)
Product Information
Applicable product:
Drop-in, integral flange, heater, left drain
Drop-in, integral flange, heater, right drain
Fixture*:
Bathing well:
Basin area, bottom
55" (139.7 cm) x 23-1/4" (59.1 cm)
Basin area, top
64" (162.6 cm) x 32" (81.3 cm)
Weight
132 lbs (60 kg)
To overflow:
Water depth
15" (38.1 cm)
Capacity
78.5 gal (297 L)
* Approximate measurements for comparison only.
Drop-in cut-out dimensions:
Pump: 1-speed
Heater: 1.5 kW
Minimum access panel
pump/control (required):
1047190-1-D
72" (182.9 cm)
3/8" (1 cm)
2-7/8" (7.3 cm)
3" (7.6 cm)
K-1114-LH
K-1114-RH
70-1/2" (179.1 cm) x
40-1/2" (102.9 cm)
V
Hz
A
120
60
7.5
120
60
12.5
20" (50.8 cm) W x
15" (38.1 cm) H
No change in measurements if connected with
drain illustrated. (K-11677 or K-11677M)
Recommended faucet area
1-1/4"
(3.2 cm)
Tile Flange
Pump/Control Access
1-1/4" (3.2 cm)
21"
19-1/2"
(53.3 cm)
(49.5 cm)
1-1/2" OD
Required Electrical Service (2 required)
Two dedicated circuits required, each protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control
Heater
Locate the outlets behind the whirlpool and within 24" (61 cm)
of the pump and heater.
Notes
Install this product according to the installation guide.
Floor support under this product must provide for a minimum of
30 lbs/square foot (142 kg/square meter) loading.
If installing a rim-mount faucet, make sure there is no interference
with the drain overflow and circulating system before drilling any
holes. Consult local and national codes for minimum air gap
requirements if installing a spout on the faucet deck.
This fixture conforms to ANSI Standard Z124.1.2. All dimensions
are nominal.
2
1-1/2"
(3.8 cm)
Drop-In Rim
Detail
Detail
42" (106.7 cm)
120 V, 15 A, 60 Hz
120 V, 15 A, 60 Hz
Kohler Co.

Publicidad

loading

Este manual también es adecuado para: