„ To keep all your coffee's aroma and to avoid a degradation of the ground coffee, empty
the ground coffee holder after each use.
„ Always disconnect the grinder before cleaning.
„ Never place the grinder, power supply cord or plug in water or under running water.
„ Do not use strong detergents or abrasive pads to clean the appliance.
„ Clean the lids and the ground coffee holder in warm, soapy water or place them in the
upper basket of your dishwasher.
„ To remove the upper burr, set the fineness selector to the fine position (8) then take
hold of the winglets of the upper mill with your fingers and turn clockwise, then raise it
vertically to remove (9).
„ Carefully clean the inside of the coffee- bean tank with a damp cloth.
„ To replace the upper burr, set the fineness selector to the coarse position, insert the burr
and turn it once in the counter-clockwise direction (10).
„ Carefully clean the ground coffee dispenser and the body of the appliance with a damp
cloth.
The appliance does not
work.
The appliance stops during
operation.
The selector of the ground
fineness does not work
anymore.
MAINTENANCE

TROUBLESHOOTING GUIDE

Check the electrical connection.
The lid of the coffee bean hopper is not correctly
positioned.
The ground coffee hopper is not correctly positioned
or the lid of the ground coffee hopper is not correctly
positioned or is not in place.
The appliance has too much heated. The thermal fuse
of the motor released. You have to contact an approved
service center.
Causes of overheating to be avoided:
The maximum capacity of beans in the bean hopper, or
the maximum capacity of ground coffee in the ground
coffee holder has been exceeded.
Check the upper burr is correctly positioned. (See
paragraph concern