ELECTRICAL CONNECTIONS (EN)

w w w. i s e o . c o m
Non contractual document. Subject to change. Cod. 6000780P002.1, Rev. 001 - 16/07/2021
Thesis 2.0 Professional Mini Installation Guide (EN) - © 2021 Iseo Serrature S.p.a. - www.iseo.com
1. APPLICATION EXAMPLE (single door)
1.
Thesis 2.0 lock
2.
Lock striking plate
3.
Cylinder
4.
Stylos reader
5.
Cable gland
6.
Opening button
7.
Spring-loaded damper
8.
Power supply
The image on the left serves only as an example of
this product in use.
Please consult the catalogue to see all available
accessories for the series Thesis 2.o, or contact us
for any technical or sales questions.
3. ELECTRICAL CONNECTIONS
1. Comunication channel (LOCKBUS)
2. Positiv - Power supply 8÷30 VDC 1A (+)
3. Negativ - Power supply GND (-)
4. Relay common contact signal (COM)
5. Normally closed relay contact signal (NC)
6. Normally open realy contact signal (NO)
7.
8÷24 VDC/12 VAC
8.
T1 opening button
(not included)
1 2 3 4 5 6 7 8
5. FUNCTION MODES
TOTAL functioning
If the opening command is of less than 1 second, the lock opens and stays open with
the door shut for the duration of the preset courtesy time. If the door is opened before
the courtesy time elapses, then the next time the door closes the lock will release the
locking valve and will secure the passage.
FREE functioning
If the opening command is active (state), the lock ignores the preset courtesy time and
holds back the unlocking bolt until the opening command is deactivated. In this mode,
access to the passage is always ensured: each time the door closes the lock does not
close ("daytime" mode).
Iseo Serrature s.p.a
®
Via San Girolamo 13
25055 Pisogne (BS)
ITALY
Tel. +39 0364 8821
iseo@iseo.com
ELECTRONIC SUPPORT SERVICE
iseo.com
7
4
6
1
3
2
5
8
Exterior
Interior
Opening command
Optically isolated entry
CAUTION
Minumum cross-section of
the power lines in relation to
the installation length:
up to 10 m section: 0.5 mm
10÷40 m section: 0.75 mm
40÷50 m section: 1 mm
50÷75 m section: 1.5 mm
75÷100 m section: 2.5 mm
Take care not to damage the
cables while fastening the
lock to the frame.
INDEX
APPLICATION EXAMPLE (single door)
MANUAL OR AUTOMATIC INTERLOCKING EXAMPLES
ELECTRICAL CONNECTIONS
FASTENING THE CABLES AND THE CONNECTOR
FUNCTION MODES
SETTING THE "COURTESY" AND "DELAYED CLOSURE" TIMINGS
RELAY CONFIGURATIONS
CONNECTIONS FOR MANUAL OR AUTOMATIC INTERLOCKING
CONFIGURATION OF THESIS 2.0 WITH STYLOS LINE
CONFIGURATION OF THESIS 2.0 WITH OFF - LINE SOFTWARE
WARNINGS
2. MANUAL OR AUTOMATIC INTERLOCKING EXAMPLES
7
5
4
1
3
2
6
Exterior
interlocked opening
4. FASTENING THE CABLES AND THE CONNECTOR
CAUTION
To protect the electronic circuit from external factors, please place the
black rubber cap between the cables and the green connector (the
black rubber cap and the removable connector are both included).
After fastening the cables to the green removable connector (1),
insert the latter into the permanent connector on the upper part of
the lock (2). Cover the connectors with the black rubber cap,
anchoring it to the lock with the screw that is provided.
6. SETTING THE "COURTESY" AND "DELAYED CLOSURE" TIMINGS
Setting the "opening time" (T1)
To modify the opening time of the lock, present by
the manufacturer at 15 seconds, proceed as follows:
-
position the powered lock to be with the bolt in
set back condition with the door open (both bolt
and door in open position);
-
press button P1 for the desired duration, between
1 and 180 seconds (while programming, the L1
LED will flash at 1 second intervals).
Setting the "delayed closure" at the closing of
the door (T2)
To modify the "delayed closure" at the closing of
the locking door, preset by the manufacturer at 1
second, proceed as follows:
-
position the powered lock to be with the bolt in
set back condition with the door open (both bolt
and door in open condition);
-
press button P2 for the desired duration,
between 1 and 60 seconds (while programming,
the L1 LED will pulse at 1 second intervals).
7
1.
Thesis 2.0 lock
2.
Lock striking plate
3.
Cylinder
4.
Stylos reader
5.
Opening button
6.
Cable gland
7.
Spring-loaded damper
8.
Power supply
ATTENTION
In the case that automatic
interlocking is installed, the
indicator lights at the openin-
gs
(4.2)
are not equipped
with an opening button.
8
NOTE
The communication channel
guarantees an encrypted
exchange
between
Interior
Thesis 2.0 locks.
CAUTION
In the event that the interlocking lock
is used with other devices through the
communication channel LOCKBUS, do
not set T2 at less than 1 second for
proper functioning.
1
2
3
4
5
6
7
8
9
10