Feature:
• 2 power outlets for battery backup and surge protection.
• 1 outlet for non data sensitive equipments such as printer/scanner/...
• Surge protection for the 3 power outlets
• 1 outlet for Tel/modem/network surge protection
• Battery status display : online – Backup – replace battery
• Sound alert for battery low load, backup mode
• Easy replaceable battery
• Automatic battery diagnostic
> Capacity 300VA 165 W
After the UPS is turned on, it automatically conducts a self-test and enter normal mode.
Press the power button for one second would also enable the self test function again.
The silence function can be enabled/disabled by pressing power button for one second under backup mode.
In addition, the power button can be used to switch on and off your UPS : press power button for two seconds
until the beep stop. Just press one to switch on your UPS.
Installation:
You could use your UPS as soon as you buy it as the battery is fully loaded before leaving the factory.
But it is recommended that you reload the UPS for 4 hours before using it as energy loss may occur during
shipping or a long duration storage. To recharge the battery, simply let the UPS plugged into a AC outlet
and switch it on.
Connecting the equipments:
Connect your primary equipments to the UPS : screen, computer...to the battery backup outlets.
Plug your other peripheral to the full time By-Pass outlet. Do not plug laser printer as its power demand is much
higher than the surge protection could support.
If you wish to protect a phone, a fax, a modem or your network interface, just plug this equipment into the OUT
outlet situated on the side of the UPS thanks to the provided cable (or thanks to another network cable
if you wish to protect your network interface). The connect your former cable into the IN outlet.
To maintain the optimal battery charge, let your UPS plugged and on all the time.
CAUTION
!
First use :
It is recommended to perform a simulation test when using the UPS for the first time, or when adding an equipment:
plug all your equipment, power on your ups and wait for few minutes, then unplug the UPS to simulate a power sag.
Make sure that the total power of your equipment does not exceed the capacity of the UPS.
Buzzer and Led status :
.............
Buzzer
>
OFF
OFF
ON
ON : 1 s - OFF : 4 s
ON : 1 s - OFF : 1 s
ON : 0.5 s - OFF : 0.5 s ON
2
UPS USER GUIDE :
> Risk of electric shock: do not remove cover
> Do not put in fire: risk of explosion
.............
Led
>
ON
ON : 0.5 s - OFF : 0.5 s Battery fault
ON : 1 s - OFF : 4 s
ON : 1 s - OFF : 4 s
ON : 1 s - OFF : 1 s
Status
AC Mode
Replace the battery.
Overload
The device requires too much power.
Unplug the device.
Backup mode
Save your documents and switch off your equipment.
Battery low
Recharge the battery.
Charger abnormal
AC overload, save your documents
and switch off your equipment.