Wall installation

Variants with removable calculator unit can be installed up to max. 40 cm away
from the flow sensor using the optional wall bracket EWA600C-WM.

Attach the user protection

The meter is delivered with two twister seals which can be used to seal the
temperature sensor and the measuring tube screw fitting.
To seal the unit proceed as follows:
(1) Thread the wire of the seal through the seal bore holes of the union nut
on the inlet, on the EAT and on the flow sensor or sensor screw fitting and
immersion sleeve.
(2) Insert the wire through the opening in the seal body and pull it tight.
(3) Fold the seal closure over and click firmly to press it completely flush to the
seal housing.
(4) Cut off excess seal wire.
Attach the spacer (a) and wall bracket
(1)
(b) in the required position using the
enclosed material. Align the wall bracket
in such a way that the groove (b1) is
pointing downwards.
Fit the cover (c) in such a way that
(2)
the marking "TOP2" can be read
horizontally, and click it into the wall
bracket.
Take the calculator unit off the flow
(3)
sensor, unwind the calculator unit
Firmly latch the calculator unit into the
(4)
wall bracket.
MU2H-0491ge23 R1020
31