Publicidad

Enlaces rápidos

Installation manual
Daikin Altherma hybrid heat pump – outdoor unit
Installation manual
EVLQ05CAV3
English
Daikin Altherma hybrid heat pump – outdoor unit
EVLQ08CAV3

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Daikin Alterna EVLQ05CAV3

  • Página 1 Installation manual Daikin Altherma hybrid heat pump – outdoor unit Installation manual EVLQ05CAV3 English Daikin Altherma hybrid heat pump – outdoor unit EVLQ08CAV3...
  • Página 2 3P344908-1B...
  • Página 3: Tabla De Contenido

    Connecting the refrigerant piping ..........Daikin website (publicly accessible). 4.3.1 To connect the refrigerant piping to the outdoor unit .. ▪ The full set of latest technical data is available on the Daikin Checking the refrigerant piping ..........Business Portal (authentication required). 4.4.1 To check for leaks............
  • Página 4: Installation

    Additionally, make sure the unit is positioned at least 100 mm above the maximum expected level of snow. In this case, it is recommended to construct a pedestal, and on this pedestal install the EKFT008CA option kit. Installation manual EVLQ05+08CA Daikin Altherma hybrid heat pump – outdoor unit 4P344906-1D – 2020.10...
  • Página 5: To Provide Drainage

    The pedestal MUST be aligned with the backside of the U‑beam. 3 Remove the protective cardboard and instruction sheet. Drain pan U-beams Protective cardboard Instruction sheet EVLQ05+08CA Installation manual Daikin Altherma hybrid heat pump – outdoor unit 4P344906-1D – 2020.10...
  • Página 6: To Prevent The Outdoor Unit From Falling Over

    Be sure to open the gas stop valve after piping installation and vacuuming. Running the system with the valve closed, the compressor may break down. Liquid stop valve Gas stop valve Service port Installation manual EVLQ05+08CA Daikin Altherma hybrid heat pump – outdoor unit 4P344906-1D – 2020.10...
  • Página 7: Charging Refrigerant

    2 Fix the label on the inside of the outdoor unit near the gas and Interconnection cable Field wiring (if applicable) liquid stop valves. Liquid pipe EVLQ05+08CA Installation manual Daikin Altherma hybrid heat pump – outdoor unit 4P344906-1D – 2020.10...
  • Página 8: Starting Up The Outdoor Unit

    Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). Piping diagram: Outdoor unit...
  • Página 9 Electronic expansion valve coil Reversing solenoid valve coil Z1C~Z4C Ferrite core Field wiring Terminal strip Connector Terminal Protective earth Black Blue Brown Green Orange Purple White Yellow EVLQ05+08CA Installation manual Daikin Altherma hybrid heat pump – outdoor unit 4P344906-1D – 2020.10...
  • Página 12 4P344906-1D 2020.10 Verantwortung für Energie und Umwelt...